Forwards LER 80-011/03L-0
Date released: 10/31/2019 Download: ML19290F015


LER 80-011/03L-0:on 800208,W/RCS at 130 Degrees & 250 Psia, Shutdown Cooling Suction Header Relief Valve Lifted & Failed to Reset.Caused by Valve Being Left at Improper Relief Pressure Due to Error Following Testing
ML19290F018
Person / Time
Site: Calvert Cliffs 
Issue date: 03/07/1980
From: Davis S, Huseby D
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19290F018 (2)
Forwards LER 80-011/03L-0
ML19290F014
Person / Time
Site: Calvert Cliffs 
Issue date: 03/07/1980
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19290F014 (1)