a Form NRC418 U.S. NUCLEAR REGULATORY CoMMIS$10N n2 73)
CERTIFICATE OF COMPLIANCE jo gpp 7, For Radioactive Materials Packetes 1.(a) Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.(e) Total No. Pages 6745 2
USA /6745/Bf )
1 2
- 2. PRE AMBLE 2.tal This certificate is issued te satisfy Sections 173.333a,173.394,173.395, and 173.396 of the Department of Transportation Harardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10s and 146-19-100 of the Department of Transportation Dangerous Cargoes Reguistions (46 CFR 146-149), as amended.
2.(b)
The packaging and contents described in item 5 below, rneets the safety standards set forth in Subpart C of Title 10 Code of Fedeval Regulations. Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.fc)
This certif 6cate does not relieve the consignor from compliance witn any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the gownrnment of any country through or into which the package will be transported.
- 3. This cartificate is issued on the basis of a safety analysis report of the package design or applicatiort-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
General Atc,mic Company General Atomic Company application dated P.O. Box 81608 December 16, 1975.
San Diego, California 92138 3.tc)
Docket No.
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71. as applicable, end the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number. Fissile Class. Other Conditions, and
References:
(a) Packaging (1) Model No.:
FSV-2 (2) Description The package consists of a right circular cylindrical containment vessel enclosed in a removable plywood overpack. The containment vessel is carbon steel 67-3/4 inches long by 44 inches OD with minimum 3-3/4 inch thick walls and ends. The closure is gasketed (asbestos) and secured by twelve, 3/4"-10 UNC bolts. Contents l
are enclosed within an additional gasketed steel inner vessel which is positioned within the containment vessel by crushable spacers located at the top and battom. The laminated plywood overpack is 94 inches long by 70 inches in diameter and provides a minimum 8-inch thick cover around the containment vessel. The overpack is secured through the base by sixteen, 3/4-inch diameter bolts. The total weight of the loaded package is 18,200 pounds.
(3) Drawing The packaging is constructed in accordance with GGA Drawing No.
T1601-452, Issue H.
i 8002220
Page 2 - Certificate No. 6745 - Revision _No. 2 - Docket No. 71-6745 5.
(b) Contents (1) Tyne and form of material Contaminated metal equipment.
(2) Maximum quantity of' material per package Not to exceed 5 watts 6.
Prior to each shipment, the asbestos Ild gasket shall be ' inspected. The gasket shall be replaced with a new gasket if inspection shows any defects or every twelve (12) months, whichever occurs first.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
8.*
Expiration date:
February 28, 1985.
REFERENCE General Atomic Company application dated December 16, 1974.
FORTHEU.S.NUCLEARREGULATORYCOMNISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety FEB 0 61980 Date:
e O
e 9