ML19290C651

From kanterella
Jump to navigation Jump to search
Forwards Ten Special Tests Proposed for Unit 1 low-power Test Program.Numbers Given in Precautions & Acceptance Criteria Sections Subj to Verification by Analysis
Date released: 10/31/2019 Download: ML19290C651


Boron Mixing & Cooldown, Special Test 9B
ML19290C664
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/15/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C664 (16)
Forced Circulation Cooldown, Special Test 9A
ML19290C663
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/30/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C663 (30)
Establishment of Natural Circulations from Stagnant Conditions, Special Test 8
ML19290C662
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C662 (22)
Simulated Loss of All Onsite & Offsite AC Power, Special Test 7
ML19290C661
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/15/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C661 (43)
Cooldown Capability of Charging & Letdown, Special Test 6
ML19290C660
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C660 (25)
Natural Circulation at Reduced Pressure, Special Test 5
ML19290C659
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/15/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C659 (30)
Effect of Steam Generator Secondary Side Isolation on Natural Circulation, Special Test 4
ML19290C658
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/15/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C658 (31)
Natural Circulation W/Loss of Pressurizer Heaters, Special Test 3
ML19290C656
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C656 (31)
Natural Circulation W/Simulated Loss of Offsite AC Power, Special Test 2
ML19290C653
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C653 (37)
Natural Circulation Test, Special Test 1
ML19290C652
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 12/14/1979
From:
TENNESSEE VALLEY AUTHORITY
To:
References
Download: ML19290C652 (31)
Forwards Ten Special Tests Proposed for Unit 1 low-power Test Program.Numbers Given in Precautions & Acceptance Criteria Sections Subj to Verification by Analysis
ML19290C650
Person / Time
Site: Sequoyah Tennessee Valley Authority icon.png
Issue date: 01/18/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: RUBENSTEIN L S
Office of Nuclear Reactor Regulation
References
Download: ML19290C650 (1)