ML19290C629

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 6581,Revision 11,for Models 51032-1 & 51032-1a
ML19290C629
Person / Time
Site: 07106581
Issue date: 01/04/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19290C628 List:
References
NUDOCS 8001220200
Download: ML19290C629 (6)


Text

g, ' Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE

,g CFR 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.ld) Pages No. 1 (e) Total No. Pages 6581 11 USA /6581/B( IF 1

6

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.lb)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any reouirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, mcluding the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

EXXON Nuclear Company, Inc.

EXXON Nuclear Company, Inc. application dated

,2101 Horn Rapids Road October 14, 1971, as supplemented.

Richland, WA 99352 3.tc) oocket No.

71-6581 4 CONDITIONS This certificate is conditional upon the fulfilling of the reouirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified

(

in item 5 below.

5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a) Pac kaging (1) Models Nos.:

51032-1 and 51032-la (2) Description A steel shipping container for fuel bundles, consisting of a strongback and fuel bundle clamping assembly, shock mounted to a steel outer container. Minimum 3/8" thick wall, 6" x 8" x 8-1/2" long steel separators are bolted between fuel bundles. Outer container is approximately 43" diameter by 216" long. The maximum weight of the package is approximately 7,400 pounds for the Model No. 51032-1 and 8,300 pounds for the Model No. 51032-la.

(3) Drawings The Model No. 51032-1 is constructed in accordance witn Applied Design Company Drawings' Nos.:

51032-1-001, Sheet 1, Rev. H 51032-1-001, Sheet 2, Rev. F 51032-1-001, Sheet 3, Rev. F 51032-1-001, Sheet 4, Rev. F 1785 130 51032-1-001, Sheet 5, Rev. H 51032-1-001, Sheet 6, Rev. F 51032-1-001, Sheet 7. Rev. H 8001200 2

Page 2 - Certificate No. 6581 - Revision No. 11 - Docket No. 71 -6581 (f.

(3) Drawings (continued) 51032-1-002, 2 Sheets, Rev. B 51032-1-003, Rev. 0 51032-1-004, Rev. B and Jersey Nuclear Company Drawings Hos.:

JN-600, 841, Sheet 1, Rev. 2 JN-600, 843, Sheet 1, Rev. 3 JN-600, 844, Sheet 1, Rev. 2 The Model No. 51032-la is constructed in accordance with Exxon Nuclear Company, Inc. Drawings Nos.:

XN-NF-303,354, Sheet 1, Rev. 0 XN-NF-303,354, Sheet 2, Rev. 0 Xil-NF-303,355, Sheet 1, Rev. 0 XN-NF-303,356, Sheet 1, Rev. 0 XN-NF-303,357, Sheet 1, Rev. 0

(

XN-NF-303,357, Sheet 2, Rev. 0 XN-NF-303,358, Sheet 1, Rev. 0 XN-NF-303,359, Sheet 1, Rev. 0 XN-NF-303,360, Sheet 1, Rev. 0 XN-NF-303,364, Sheet 1, Rev. 0 XN-NF-302,231, Sheet 1, Rev. 4 (b) Contents Type, form, and maximum quantity of material per package shall be as follows:

(1) Sintered oxide pellets (UO2 or Pu0 -UO ) as fuel rods.

2 2

The fuel rods are assembled into fuel assemblies by upper and lower tie plates and intermediate spacers.

The EXXON Nuclear type identification, radioactive material, fissile constituents, and maximum number of assemblies per package is as follows:

e 1785 131.

Page 3 - Certification No. 6581-Revision No.11 - Docket No. 71-6581

(..

(5)(b)

Contents (continued) ilaximum No. of Radioactive Material Fissile Constituents Assemblies per XN I.O.

I.D. Max. Total Quantity I.D. Maximum Quantity Packaae (kg/ Package)

(kg/ Package)

TYPE I(a)

U 247 U-235 6.1 2

Pu 3.0 Pu 2.5 f

TYPE II(a)

U 368 U-235 9.8 2

TYPE III(b)

U 236 U-235 5.3 4

Pu 1.7 Pu 1.4 f

TYPE IV(c)

U 414 U-235 17.0 2

TYPE V(c)

U 375 U-235 6.0 2

TYPE VI(c)

U 375 U-?.3 5 10.0 2

TYPE VII(c)

U 362 U-235 8.0 2

Pu 2.5 Pu

2. 0 f

'.(PE VIII(c)

U 510 U-235 16.0 4

Pu 6.0 Pu

5. 0 f

TYPE IX(c)

U 142 U-235 4.0 2

TYPE X(c)

U 238 U-235 6.0 2

TYPE XI(d)

U 750 U-235 26 2

TYPE XII(d)

U 810 U-235 23 2

TYPE XIII *)

U 400 U-235 10 2

I TYPE XIV(*)

U 510 U-235 23 4

Pu 6.3 Pu 5.0 f

TYPE XV *)

U 550 U-235 22 4

I (a)

See Tables, application dated flovember 9,1971.

(b) See Tables, application dated September 11, 1972.

(c) See Tables, 2.4 through 2.11, application dated November 15, 1972.

(d) See Tables, 2.4-111 and 2.11, application dated July 17, 1973.

(e) See Tables 2.4-IV, 2.5-IV, and 2.6-IV, application dated December 18, 1973.

1785 132

Page 4 - Certification No. 6581 - Re/ision No.11 - Docket No. 71-6581 E

(5) (b)

Contents (continued)

Maximum No. of Radioactive ilaterial Fissile Constituents Assemblies per XN I.D.

I.D. Max. Total Ouantity I.D. Maximum Quantity Packace (kg/ Package)

(kg/ Package)

TYPE XVI( )

U 900 U-235 28 2

TYPE XVII (f)

U 240 U-235 5.0 2

Pu 1.8 Pu 1.4 f

TYPE XVIII(f)

U 840 U-235 26 2

TYPE XIX(9)

U 230 U-235 8.4 2

TYPE XX(9)

U 480 U-235 20.0 2

TYPE XXI(h)

U 250 U-235 9.8 2

TYPE XXII (i)

U 789.6 U-235 18.5 2

TYPE XXIII(i)

U 195 U-235 4.5 2

iii)E XXIV (d)

U 300 U-235 7.5 2

  • TYPE AA(k)

U 1080 U-235 35.65 2

II)

TYPE XXV U

766 U-235 25 2

TYPE XXVI(I)

U 766 U-235 26.5 2

TYPE XXVII(I)

U 874 U-235 27.1 2

I)

TYPE XXVIII U

352 U-235 10 2

(f) See Tables 2.4-V, 2.5-V, and 2.6-V, application dated June 28, 1974 (g) See Tables 2.4-VI and 2.5-VI, application dated April 15, 1975.

(h) See Tables, applications dated January 20, 1976 and January 26,1976.

(i) See Tables, application dated June 22, 1976.

(j) See Table, application dated September 14, 1976.

(k) See Table, application dated December 22, 1977.

(1) See Table, application dated Decem,ber 13, 1978.

  • Authorized for the Model No. 51032-la only.

1785 133

Page 5 - Certificate No. 6581 - Revision No.11 - Docket No. 71-6581 (b) Contents (continued) 2 or Pu0 -UO ) as Zr clad fuel rods packaged (2) Sintered oxide pellets (UO 2

2 within the inner wooden container described by Exxon Nuclear Drawing No.

XN-301, 901, Rev. O.

The package may contain up to nine (9) fuel rods having a maximum enrichment of 5.0 wt% fissile elements (23sU, 239pu, and 241Pu; where the isotope 241Pu is to be limited to less than 10 w/o of the total Pu) with a maximum pellet diameter of 0.5 inches.

Inert Zr rods may be additionally included.

Sintered mixed oxide pellets (Pu0 -UO ) as Zr clad fuel rods packaged (3) 2 2

within the inner wooden containers described by Nuclear Fuel Services Crawing No. RMG-650 B.

The package may contain up to twenty-two (22) rods having a maximum enrichment of 5.0 wt% fissile elements (2350, 239pu, and 2'*1Pu; where the isotope 241Pu to be limited to less than 10 w/o of the total Pu) with a maximum pellet diameter of 0.5 inches.

(c)

Fissile Class I and lII (1) Class I Type IV through X, XIII, and XVI through XXVIII and Type AA assemblies described and limited in 5(b)(1).

(2) Maximum No. of (i) Type I, XI, and XII, assemblies described Packages per and limited in 5(b)(1):

Shipment as Class III One (1) Package (ii) Type II assemblies described and limited in 5(b)(1):

Two (2) packages (iii) Type III assemblies described and limited in 5(b)(1):

Five (5) packages (iv) For the contents described and limited in 5(b)(2) and (3)

One (1) package (v) Type XIV and XV assemblies described and limited in 5(b)(1):

Eight (8) packages 1785 134

Page G - Certificate No. 6581 - Revision No.11 - Docket No. 71-6581 t

6.

Each fuel assembly shall be enclosed in an unsealed polyethylene sheath which will not extend beyond the ends of the fuel assemblies.

The ends of the sheaths shall not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assemblies.

Polyethylene shims and ethafoam pads may be used in the packaging of all fuel assemblies as described in the December 18, 1973 application except for Types IV and V.

7.

The package may contain an additional Zr clad fuel rod. The rod shall be limited to 4.J kg of uranium enriched in the U-235 isotope to not more than 3.0% by weight. The rod shall be packaged as shown in EXXON Nuclear Company, Inc. Orawing No. XN-601, 825, Rev. O.

d.

The package authorized by this certificate is hereby approved for use under the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

9.

Expiration cate:

July 31, 1980.

REFERENCES EXXON Huclear Company, Inc. application dated October 14, 1971.

ipplements dated: November 9 and December 8,1971; September 11 and 21,1972; March 2, valy 17, November 20, and December 18,1973; June 28,1974; February 8, and April 15, 1975; January 20 and 26, June 22, and September 14, 1976; and December 13, 1978.

For tne contents described in 5(b)(3):

Nuclear Fuel Services application dated July 8, 1977.

In additon for the Model No. 31032-la, Exxon Nuclear Company, Inc., application dated December 22, 1977 as supplemented March 1, May 2, and :iay 26, 1978.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION k

%OLy

~

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

2

  • I330 1786 1%