ML19290C614

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5026,Revision 6,for Model CNS 14-190
ML19290C614
Person / Time
Site: 07105026
Issue date: 01/08/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19290C612 List:
References
NUDOCS 8001220173
Download: ML19290C614 (3)


Text

.

Form NRC418 U.S. NUCLE AR REGULATORY COMMISSION

~

CERTIFICATE OF COMPLIANCE

,g CFR 71 For Radioactive Materials Packages 1.(4) Certificatt Number 1.(b) Revision No.

1.(c)

USA /50e Identification No.1 3

Pack

  • 1'd) Pages No. 1.(e) Tote No. Pages 26/B( )

5026 6

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transportation Hazarous Materials Regulations (49 CFR 170189 and 14 CFR 103s and Sections 146-19-10a and 146-19-100 af the Department of Transportation Dangerous Cargoes Regulations (46 CFR 148-149), as amended.

2.(M The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 7*, Packaging of Radioactive Materials for Tra1 sport and Transportation of Radioactive Materia' Under Certain Conditions."

2.(c)

This certificato does not relieve 'he consignor from compliance with any requirement of the egulations of the U.S. Department of Transportation or other applical.,se regulatory agencies, including the government of any country through or into which the package will be transported.

3./This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Chem-Nuclear Systems, Inc.

Chem-Nuclear Systems, Inc.

P.O. Box 1866 Application dated November 19, 1979.

Bellevue, WA 98009 3.(c)

Docket No.

71-5026

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents. Mcdel Number, F.ssile Class. Other Conditions, and

References:

(a) Packaging (1) Model No.:

CNS 14-190 (2) Description The packaging is a steel-encased, concrete shielded shipping cask.

The cask is 94-1/4 inches in diameter by 103-3/4 inches in length.

Reinforced concrete occupies the seven inch annular space between the shells and the two base plates. The lid is a 4-3/4 inches thick laminated steel cover held in place by thirty-two, high strength 1-1/4-inch diameter bolts. A silicone 0-ring is used to seal the joint between the lid and the ca.k body. The outer shell and base plate are 1/4 inch thick, while inner shell and base plate are 2 inches thick. The cask is reinforced at the top and bottom with steel rings and is equipped with lifting lugs.

The lid is provided with two access ports. Gross weight is about 71,000 pounds.

(3) Drawings The package is constructed in accordance wit.1 the following-ATCOR, Inc. Drawings Nos.: 1000-D-0049; 0146-B-0004, Rev. E; 0146-B-0009; 0146-D-0025, Rev. A; 0146-D-0020-1, Rev. A; and 0146-C-0018, Rev. E.

785 W 80 012 20 l7,_3 4

W '.

Page 2 - Certificate No. 5026 - Revision No. 6 - Docket No. 71-5026 (b) Contents (1 ) Type and form of material (i) Byproduct material in the form of solids and solidified waste contained within secondary container (s).

(ii) Radioactive material in the form of activated reactor components packaged in secondary containers.

(2) Maximum quantity of material per package

~

Greater than Type A quantities of radioactive material, not to exceed 20 thermal watts and 23,000 pounds including weight of the contents, secondary container (s) and shorina.

6.

The dose rate from the loaded cask shall not exceed 10 mrem /hr at six feet from the surface of the cask.

7.

The access plugs shall be aporopriately pluqqed and sealed p-ior to transport.

8.

Shoring shall be placed between the secondary container (s) and the cask cavity to prevent movement during normal and accident conditions of transport.

9.

Prior to each shipment, the packaging lid silicone 0-rina shall be inspected. The 0-ring shall be replaced with a new silicone 0-ring if inspection shows any defects or'every six (6) months, whichever occurs first.

10. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
11. Expiration date: January 31, 1985 1785 057

~

Page 3 - Certificate No. 5026 - Revision No. 6 - Docket No. 71-5026 REFERENCE Chem-Nuclear Systems, Inc. application dated November 19, 1979.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

JAN O 81980

\\

r O

~ 1785 058 m

'