Requests Addl Info Re Consolidated Application for Renewal of Certificate of Compliance 6275 for Model CNS 0-4 (LL-28-4).Addl Info Should Be Submitted as Revised Pages to Consolidated SAR
ML19290C604
Person / Time
Site: 07106275
Issue date: 01/08/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Reynolds L
CHEM-NUCLEAR SYSTEMS, INC.
References
NUDOCS 8001220156
Download: ML19290C604 (2)


Text

fD!!

pe acuq 4

k UNITED STATES y

(

g NUCLEAR REGULATORY COMMISSION 5

C WASHINGTON, D. C. 20555 k+..../

J.Ul 0 3 S30 FCTC: RHO 71-6275

\\

Chem-Nuclear Systems, Inc.

ATTN: Mr. Louis E. Reynolds P.O. Box 1866 Bellevue, WA 98009 Gentlemen:

This refers to your consolidated application dated November 19, 1979, requesting renewal of Certificate of Compliance No. 6275 for the Model No. CNS 0-4 (LL-28-4) shipping package.

In connection with our review, it will be necessary to revise certain sections within the consolidated renewal application to make it consistent with the previous approval.

1.

The previous approval is based on the inner liner or encapsulatior, providing containment.

Section 1.2.1 (p 1-5) and Section 4.2.2 (p 4-1) state the cask itself is the primary containment vessel. Neither the drawings nor Section 1.2.1 indicate the cask is provided with a seal.

Also, the cavity vent and drain lines are not sufficiently protected for the impact tests.

It must be concluded that the cavity is vented to the atmosphere.

2.

The consolidated application does not contain the information previously submitted concerning the adequacy of cask cover fasteners.

3.

Section 1.2.3 (p 1-6) requests package contents which differ from the contents previously approved.

4.

ATC0R drawings referred to in Items 6 and 7 of the previous approval (Revision 5) have not been provided. Also, Drawing Nos.1000-E-0040-0 and 1000-E-0041-0 apparently show features which are not consistent

~

with those on Drawing No.1000-R-0043-0 (e.g., the 571/2 inch long angles at the top of the closure).

The application should include consolidated drawings of the package design-1785 052 ao ot c eo isc g

30 Chem-Nuclear Systems, Inc. -

Please provide, within thirty (30) days from the dati of this letter, the information requested above. The additiona) informa61on requested by this letter should be submitted in the form of revised pages to the consolidated Safety Analysis Report !n order to preserve the continuity of your appli-cation.

If you have any questions regarding this matter, we will be pleased to meet with you and your staff.

Sincerely,

~

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety 1785 OSc3

      • o' e**

. 9

_