4 U. S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT REGIOi7 IV Report No.
99900377/79-01 Program No. 51400 Company:
Victoreen Incorporated Subsidiary of Sheller - Globe 10101 Woodland Avenue Cleveland, Ohio 44104 Inspection Conducted: August 9-10, 1979 Inspector:
/k N// 7f
/
u --
p J.f.Agee,CContractorInspector
'Date ComponentsSection II Vendor Inspection Branch Approved by:
M
[O !2 '2)
D.M.Hunnicutt, Chief {
\\
Date' ComponentsSection II Vendor Inspection Branch
'Summarv Inspection on August 9-10, 1979 (99900377/79-01)
Areas Inspected:
Implementation of 10 CFR 50 Appendix B criteria and applicable codes and standards including:
initial management meeting, and QA Manual / Program.
The inspection involved twelve (12) inspector-hours on site by one (1) NRC inspector.
Results:
In the two (2) areas inspected two (2) deviations were identified as follows. No unresolved items were identified.
Deviations: QA Mansul did not describe the functions, responsibilities and authority of senior management personnel in marketing, engineering and procurement whose activities affect quality (See Notice of Deviation, Item A).
Audits Records - QA Manager's looseleaf file containing audit records was not
_ current and did not contain all audit records (See Notice of Deviation, Item B).
1726 239 g11ood