ML19290B834

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5059,Revision 6,for Model NFS Uranil Nitrate Tank Trailer
ML19290B834
Person / Time
Site: 07105059
Issue date: 12/04/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19290B833 List:
References
NUDOCS 7912140215
Download: ML19290B834 (3)


Text

.

Form NRC-618 U.S. NUCLE AR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1 (d) Pages No. 1.(e) Total No. Pages 5059 6

IKA/ROR4/AF 1

3

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

g 2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.M Title and identification of report or application:

Nuclear Fuel Services, Inc.

Nuclear Fuel Services, Inc. application P.O. Box 218 dated May 18, 1965, as supplemented.

Erwin, TN 37650 3.(c)

Docket No.

71-5059

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of 'lubpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents. Model Number, Fissile Class Other Conditions, and

References:

(a) Packaging (1) Model No.:

NFS Uranyl Nitrate Tank Trailer (2)

Description Bulk liquid insulated cargo tank trailer.

The 3,800 gallon tank railer is of all welded construction of type 304L stainless steel.

(3)

Drawings The tank trailer is constructed in accordance with D0T specifications MC-310, MC-311, or MC-312.

(b) Contents (1)

Type and form of material Uranyl nitrate in dilute acid solution.

The maxi [num U-235 enrichment in +he uranium shall not exceed 20% by weight.

The U-235 content of the solution shall not exceed 10 grams per liter and the U-233 concentration shall not exceed 1% by weight of the U-235 concentra-tion.

Plutonium content of tank trailer shall not exceed twenty (20) curies.

1574 004 7912140215

Page 2 - Certificate No. 5059 - Revision No. 6 - Docket No. 71-5059 5.

(b) Contents (continued)

(1) Type and form of material (continued)

The total uranium content shall not exceed 357 grams per liter (1.5M).

The U0 (NO )2-6H O content shall not exceed 2

3 2

50 weight percent. The HNO3 concentration will be nonnally 0.4M.

The freezing temperature of any of the solutions shall be Tess than 32 F.

(2) Maximum quantity of material per package Not more than 45,600 pounds net weight of uranyl nitrate acid solution.

(c) Fissile Class III Maximum number of packages per shipment One (1) 6.

The solution shall be at a temperature of 68 F or above at the time of packaging.

7.

Prior to delivery to a carrier for transport, for U-235 enrichments greater than 4% by weight the shipper shall ensure that at no point along the proposed shipping route that the ambient temperature will be less than 32 F.

In the event freezing weather is encountered the administrative procedures and controls as specified in Nuclear Fuel Services, Inc. application dated May 18, 1965 shall be complied with for all U-235 enrichments.

8.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date:

December 31, 1980.

1574 005

v J

Page 3 - Certificate No. 5059 - Revision No. 6 - Docket No. 71-5059 REFERENCES Nuclear Fuel Services, Inc. application dated May 18, 1965.

Supplements dated: September 20, 1966; and January 27 and February 11, 1969.

Department of Energy application dated December 23, 1977.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION k

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

1574 006

~