ML19290A459

From kanterella
Jump to navigation Jump to search
Action Control Form CDR 139 Re Request for Evaluation of Technical Adequacy of Corrective Action & Final Resolution of Deficiency Found in Valves within RCS Boundary Over One Inch Nominal Pipe Size
ML19290A459
Person / Time
Site: Crane Constellation icon.png
Issue date: 07/23/1973
From: Jennifer Davis
US ATOMIC ENERGY COMMISSION (AEC)
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML19290A453 List:
References
CDR-139, NUDOCS 7911070636
Download: ML19290A459 (1)


Text

J. P. O'R_ illy h^~

~

Region I FS&E3 ACTICN CC!:T2CL FORM A.

Action Code CDR#139 Na=e of Licensee and Facility Metropolitan Edison Co. (TMI)

Docket No. or License No.

50-289 Title Valve Uall Thickness Verification Origin Metropolitan Edison Co=pany Date Rec'd 7/18/73 B.

FS6EB Branch Coordinator:

Bryan Dreher X

Ellis Paulus Cor:plet, ion Requested by C.

Action Requested of:

ADRIMP M&PPOB EPB RPB ADC0 l

OB CB TAB 00E Region I

.g Date Requested 7/23/73 Co=pletion Reques ted by l

Reference CDR dated 7/12/73 (Miller to O'Reilly).

l D.

Action Requested In accordance with PI 0600/6, Construction Deficiency Reporting, the Metropolitan Edison deficiency report of 7/12/73 covering thin wall valve review is being assigned to Region I for evaluation of technical adequacy of the corrective action being taken and final resolution of I

the deficiency.

E.

Date Action Co=pleted Close-out (Date & Method)

Com=ents: If completion date is not consistent with your work schedule, please let us know.

1557 327

^

\\

f

'/,. G. Davis, Deputy Director for Field Operations Directorate of Regulatory Operations 4

  1. 911070[ %

P