ML19290A433

From kanterella
Jump to navigation Jump to search
Supplements Providing Proposed Schedule for Completion of Corrective Action Re Valves Containing Limitorque Operators Installed or to Be Installed
ML19290A433
Person / Time
Site: Crane 
Issue date: 03/06/1973
From: John Miller
METROPOLITAN EDISON CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 7911070616
Download: ML19290A433 (5)


Text

~

! L-c -

l ' r ;r r

)t,,,.,,",..

r 1

+

'cs - :

i,' E",0 i' 0 U T E S;.

ec.

ru s-9..

,....c m_.

  • s < sr - 2 a..

is:::0 5.t v a r< =

F).Cn ie f, Pe ctor Co.' :tr. 3r.

'!ETROPOLITA'I EDISO:' CO'IPXPt CCOD j

RO Cnief, R;cetor T&O Br.

~

RO:I!Q (4)

THRU MILE ISLLGD LTIT 1 care Directorate of Licens.ng (4) 1 LR Cantral i~iles /

"LT'!TTOPnTT '1 \\T/7F9" T Q g '. r. w, ar.1 v a rts ih!TI Ad A L 4 a A F.5 GC Attached is a letter from 'det Ed dated 3/6/73 PD" i

Local PDR cATt undating the inforr.ation contained in their I

?'S IC DTIE lotter of 1/5/73 on tha o h n'ra c ubj e c t.

To e. a -.. a-3 n.o ur.Aa uwAams State of Pennsylvania CATE i

F Ro M (N ame aa.d.r. t' REMARR$

j l

E. M. Howard, R0:1 i

  • J z.% _
  • l

.O PHO*lE *iO.

DATE 3450 3/9/73 LSE CTNER SiCE FCR AOCITIOmaL REMARKS cro to t. 7 l

1557 292 3911070

/6

,1S l

/

/

J.'7m -?. / 7 g-w.R ' -;'

/

v/;,...

/

roerrn rca roxnss

..s

/

/ METROPOLITAN EDISON COMPANY.~.

. m cr a. ~:u: vw sc unur:e: cmon.mc:

/

'OST OFFICE BOX 542 READING, PENNSYLVANI A 19603 TELEPHONE 215 - 929-3001 March 6, 1973 Mr. James P. O'Reilly, Director Region I Directorate of Regulatory Operations United States Atomic Energy Commission 970 Broad Street Newark, New Jersey 07102 SUBJECr: THREE MILE ISLAND NUCLEAR STATION UNIT #1 DOCKET NO. 50-289

Dear Mr. O'Reilly:

In m'/ letter to you dated Januar'; 5, 1973 I provided a proposed schedule for completing corrective action to resolve the Limitorque valve operator problem for TMI Unit #1.

This letter will serve to provide you with an update of the Limitorque situation.

During our investigation to determine the number of valves containing Limitorque operators installed, or to be installed, on TMI Unit #1 we found that a total of 127 valves were suspect.

(See enclosed list).

This total is slightly higher than the number (115) s tated in our January 5,1973 let ter.

Thirty seven of the suspect operators are on B & W supplied valves.

Replacement torque switches for the 37 B & W valves were received at the site on 2/5/73.

Limitorque has suggested that the torque switches be replaced on the remainine 98 valves & Met-Ed concurs with the proposal.

The 90 replacement torque switches will be shipped to the site about 4/1/73.

Should there by any questions regarding the information contained in this letter please contact me i=nediately.

p Very truly yours,/

n j

v y{/ %

1 w. ' /yn s

John G. Miller Vice President asb 1557 293 Enclosure

TMI UNIT #1 LIMITOROUE VALVE OPERATORS SMB-00, SM3-000 Valve Tag No.

Vendor Operator-SM3 Limitorcue Order Serial No.

AS-V-4 Walworth 00 336542R 9454A CA-V-13 Hancock 000 345115A 114133 CA-V-194 000 342570A 108666 CO-V-40A EMI 00 335474 92161A CO-V-40B 00 92160A CO-V-40C 00 CO-V-40D 92159A 00 92156A C0-V-40E 00 92162A CO-V-40F 00 C0-V-41A 92157A 00 92153A C0-V-41B 00 92163A C0-V-41C 30 CO-V-41D 92164A 00 C0-V-41E 92158A 00 92154A C0-V-41F 00 Co-V-111A Walworth 000 342716A 108495 92155A CO-V-111B 000 CW-V-5A Pratt 000 338490B 103234 108494 CU-V-50 000 CW-V-18A Allis Chalmers 00 335472C 100860 103233 CW-V-18B 00 CW-V-1SC 100861 00 CW-V-18D 100859 00 CW-V-14A 100858 00 335472D 100884 CW-V-14B 00 CW-V-14C 100868 00 CW-V-14D 100869 00 CW-V-14E 100885 00 CW-V-14F 100882 00 CW-V-14G 100867 00 CW-V-14H 100866 00 DH-V-23A Hancock 000 342570B 108669 200883 DH-V-23D 000 EF-V-1A 108671 000 338510E 100323 EF-V-1B 000 EF-V-4 100324 00 3365420 94543A EF-V-5 00 94544A GS -V-1 Crane 000 348345A 121520 GS-V-4 Chapman 000 3481673 120672 GS-V-5 000 1208S1 IC-V-20 Hancock 000 342465A 108296 IC-V-79A 000 356390A 137497 IC-V-79B 000 137495 IC-7-79C 000 IC-V-79D 137496 000 137498 1557 294

. Valve Tae No.

Vendor Ooerator-SFS Limitorcue Order Serial No.

MS-V-16A Hancock 000 342465A 108295 FG-V-16B 000 108293 MS-V-16C 000 108204 MS-V-16D 000 108297 NR-V-1A Pratt 000 338510B 101335 NR-V-1B 000 101336 NR-V-lc 000 101337 NR-V-8A 000 338510C 101345 NR-V-8B 000 101349 NR-V-8C 000 101347 NR-V-8D 000 101344 NR-V-10 000 101346 NR-V-10 000 101343 NR-V-15A 000 101348 NR-V-15B 000 101342 NR-V-16A 000 101340 N R-V-16B 000 101339 NR-V-16C 000 101341 NR-V-16D 000 101338 NS-V-4 Walworth 00 336542I 94541A NS-V-15 00 336542V 106780 NS-V-16A 00 336542U 100966 NS-V-16B 00 100967 NS-V-32 00 336542V 106779 NS-V-35 00 106781 RC-V-28 Hancock 000 344553A 120759 RC-V-35 000 357451A 139791 RR-V-1A Pratt 000 338510A 101334 101333 RR-V-1B 000 RR-V-5 000 338510D 101350 SR-V-1A 000 338490A 103232 SR-V-1B 000 103230 SR-V-lC 000 103231 TD-V-1A G.E.

000 342324A 109034 TD-V-1B 000 109033 TD-V-lC 000 109031 TD-V-lD 000 109032 TD-V-2 000 109030 TD-V-3A 000 109035 TD-V-3B 000 109036 WDG-V-2 Hancock 000 342570A 108667 WDG-V-3 000 342570B 103670 WDL-V-30 2 000 342570A 108665 WDL-V-303 Aloyco 000 323491A 110174 WDL-V-305 Hancock 000 342570A 108668 1557 295

TMI UNIT #1 B&W Reference NSS-5 LIMITOROUE VALVE OPERATORS SMB-00, SMB-000 B&W Sub-Limitorque Valve Tae No.

Vendor Operator-SMB Shon Order Serial No.

BS-V-2A Aloyco 000 349655A 121481 BS-V-23 000 121485 BS-V-3A 00 341166A 103983 BS-V-3B 00 103984 BS-V-4A 000 341174C 104910 BS-V-4B 000 104909 CA-V-1 Rockwell 000 337143A 98101A CA-V-3 000 337154A 100716 CA-V-4A 000 337143A 98098A CA-V-4B 000 337154A 100714 CF-V-2A 000 337143A 98100A CF-V-23 000 337154A 100717 CF-V-3A 000 337143A 98099A CF-V-3B 000 337154A 100715 DH-V-7A Aloyco 000 341174C 104908 DH-V-7B 000 104907 IC-V-1A Walworth 000 336584B 98513A IC-V-1B 000 98512A IC-V-2 000 336584A 98511A MU-V-1A Rockwell 00 337635A 99470A MU-V-1B 00 99471A MU-V-2A 00 337635C 100038 MU-V-2B 00 100039 MU-V-8 Fisher 000 342033A 108534 MU-V-12 Aloyco 000 341174C 104911 MU-V-25 Rockwell 00 337602A 100037 MU-V-33A Velan 000 360300A MU-V-33B 000 MU-V-33C 000 MU-V-33D 000 MU-V-36 000 360200B MU-V-37 000 MU-V-38 000 360200C MU-V-39 000 RC-V-2 Dresser 00 3381633 104595 RC-V-3 Rockwell 00 337610A 97213A RC-V-4 00 337110A 101234 1557 296