7 TMI DOCUMENTS Y

O.TY

~

DOCUMENI NO:

S'..

.=

~

COPY MADE ON OF DOCUMENI PROVIDED BY METROPOLITAN. EDISON C012ANY. :

.g Supervisor, Docu:nent Control, NRC e

p.

<ea e

e D

m 2221 194

~

791001og.gg.

O e

emNm m-,

m ~

~---.m P* N * ~ ~

' BA8C0CK & WILC0X COMPANY ER GENERATION GROUP

~

~

o.l ENGINEERING OPERATIONS MANAGER

  • E.A. WOMACK From os $63.:

. PLANT DESIGN / SAFETY TEAM -EJh0TR.EL)

}

V File No.

Cust*

~

Q..'.

or Ref.

Date 2:00 PM Subj.

RC PRESSURE INDICATIONS AND ERROR ADJUSTMENTS

' APRIL 8,1979

..d

a...H.' air-l m. i.ee., e............e.-..

THE FOLLOWiNG WILL CLARIFY APPROPRIATE PRESSURE INDICATIONS, INSTRUMENT STRING ERRORS (INCLUDING RADIATION EFFECTS) AND READA3ILITY ERRORS TO BE USED WHEN IMPLEMENTING B&W AND IMI-2 OPERATING EMERGENCY PROCEDURE REFERENCING RC PRESSURE. THE PRESSURE.' SIGNAL WHICH SHOULD BE USED IN CONJUNCTION W'ITH RC '

~

PRESSURE LIMITATIONS IS ONE FROM A HOT LEG PRESSURE SENSOR IN THE LOOP WITH THE RUNNING RC PUMP.

IF THIS SIGNAL IS READ FROM THE COMPUTER, ONLY_THE

^

h' INSTRUMENT ERROR NEEDS TO BE CONSIDERED. HOWEVER, IF THE PRESSURE INDICATION IS

/

I M DIRECTLY IN THE CONTROL ROOM, BOTH THE INSTRUMEN'T ERROR AND THE READABILITY ERROR SHOULD BE APPLIED. ALL B&W PROCEDURES ARE CURRENLTY BEING REVIEWED TO ENSURE THEY WILL CLEARLY REFLECT THIS PHILOSOPHY WITH RESP.ECT TO RC PRESSURE SIGNALS AND ASSOCIATED ERROR.

INSTRUMENT STRING READABILITY

~

ERROR ERROR TOTAL WIDE RANGE PRESSURE INDICATOR (0-2500 PSI) i 100 PSI i 50 PSI i 150 ?

NARROW RANGE PRESSURE INDICATOR (0-500 PSI)*-LOOP A ONLY i 20 PSI i 10 PSI i 30 ?

  • THIS SIGNAL IS NOT AVAILABLE FROM THE COMPUTOR.

B&W HAS PERFORMED CALCUIATIONS WHICH SHOW A LOOP A PRESSURE TAP TO LOOP B PRESSURE TAP LOCATION PRESSURE DIFFERENCE OF 14.PS,I (LOOP B HIGHER THAN LOOP A)

Q W1TH ONt RC PUMP RUNNING 1N t00P A.

IN vrEW OF THE POSSIBtt PRESSURE S1CNit.AnD 2'221 195

~

~

'***=**w

+=--we-e==%

., w a

g.7,-

=

/% -

i J.R. SMOTREL TO E.A. WOMACK

- SUBJECI: RC PRESSURE INDICATIONS AND ERROR ADJUSTMENTS PAGE #2 APRIL 8,1979 READABILITY ERRORS ASSOCIATED WITH THIS INSTRUMENTATION, IT IS QUITE-l REASONABLE TO EXPECY INSTANTANEOUS PRESSLTC DIFFERENCES FROM SE'1 SORS IN

~

i t LOOP A AND LOOP B 0F 50 PSI AS WAS.REPORIED EARLIER FROM THE SITE.

'. =

JRS:mue cc: D.H. ROY LONG TERM COCLIliG TEAM A

CONTROL AND INSTRUMENTATION TEAM PUMPS FLUID SYSTEMS FUEL / CORE SERVICE MANAGER LICENSING MANAGER CONTROL ANALYSIS PROCEDURE COORDINATION PROCEDURE REVIEW HEAVY COMPONEhTS