ML19289F784

From kanterella
Jump to navigation Jump to search
Contract:Verification of Exxon Technique for Stability Calculations, Awarded to Nuclear Associates Intl
ML19289F784
Person / Time
Issue date: 05/01/1979
From: Dougherty D
NRC OFFICE OF ADMINISTRATION (ADM), NUCLEAR ASSOCIATES INTERNATIONAL
To:
Shared Package
ML19289F782 List:
References
CON-FIN-B-6805, CON-NRC-03-79-150, CON-NRC-3-79-150 NUDOCS 7906160040
Download: ML19289F784 (6)


Text

--

'Aut U

I AW ARD/ CONT R ACT

]

g RM 2 6. JULY 1966

  • ST AC ARD F O.ds Ao-sn.no~
4. CtantitD FCe NATIONat DUEN5E UNDI8 sosA Ge ~tt t sn'.

FtO PROC. RtG (elCiti 8-14 408

3. REQUl$lTION/ PURCHASE Stout 5f /PtoltCT NO.

Bli. 2 AND/OR DA's atG. l.

2f ff f tCTfvt DAf t

[gq.471tACf f."r.c. f.ss ida.f.) NO.

=AnNG IRC 03-19-150 (TASK 4)

MAY

7. OfuVity (QD{

ICS r** $10

6. ADMINI$ftRLD BY CODE (if. sher chan black 1)

O N A' O~

3 IS5UED SY U.S. Nuclear Regulatory Commission

~

' ' ' ~ >

Orm isu Division of Contracts Washington, DC 20555

9. DesCOUNT fos PaOmPT PATMENT FACILITY CODE 8 CONTRACTOR CODE NAME AND' ADDRESS Nuclear Associates International A Division of Control Data Corporation r 5,,,,,.

,i,,.

10. Susuti DNVOsCES (4.. pies..la s s.sber u ise a..,,. 5 m,.

6003 Executive Boulevard spuv,s> 10 ADDitss saO-N iN uCCc Rockville, Maryland 20852 See Article XIV of B0A CODE

12. PAYMENT WILL BE MADE By II. 5 HIP TO/ MARK FOR CODE U.S. Nuclear Regulatory Commission Division of Systems Safety ATTN:

Dr. Zolton R. hosztoczy

_ Washington._DC 70555 t o u.s c. 2304 (.X

)

ADVERD$tD, f, NtGOTIATID. PUR5UANT TO:

O u u.s C. 252 <<x10 la tsis reOCUntutNT Was ACCOUNTING AND APPROPt1ATION DATA Obl i gate: $28,739.00 la B-6805 20-19-03-03-2 31X0200.209 20.

17.

18.

19 AMOUNT 16.

C U A NTIT Y UNIT UNif PRICE 13 SUPPut S / $tRVicts lit M NO This Cost-Plus-Fixed-Fee Contract is issued pursuant to the terms and conditions of Basic Ordering Agreement Number NRC-03-78-129-02 for core thermal-hydraulic analysis for light water reactors.

I Task 4: Verification of Exxon Technique for l

l Stability Calculations 2228 071 9

iva b ne, 3

Tot a ' _ fns t -Phis CONTRACTING OFFICER lt'lLL COAIPLETE BLOCK 22 OR 26 AS APPL 1 v e F.*

go. D AwAnD (C. orser.r is..e res., ired s. > ige obis Juume r.)

SG CONsnACTOe's NEGOr\\ArtD AGettutNT (C..or.cu.r is required o. sig.r

- e.at.d..e **

.. s.t.< ;,.,

N..s.,_

f.e:

. d d.......,

,6.....

.d. 6, y.

. h., n. d d.n...., < 6..........e #.,,h 3 urias u. hs.,ing.fice.J C

,,.o., eg.

i.e

.>...d d.i...,.it

....,p.,#..

.e#en...,.......,r

,,h.,..

.b..., 6. s. 6,.u.,,.4.. i. es.,u.. o.a. 6.....d h

shi. J

.ees..d vera r.

h....

a 6.....

h so.....e. - (ei r.. d.b.....a

.x.... t o, e....;4.....

...a y n.....,4......... r h.....,.,,.k e h.........s i. v ii.... e f ac.

..a.ad r a e'.',.ad (b)

'h*

.=*'d*a***'

h*

T..,w...d.br...n....#w.. p.,....e.en....

.o.h.n b...S,,o e...a

..d b r ik e.n

.as d.c.a...- (.) sh..-.ed./..a',.d. (b) th. whu.h.a, d.ar.

w..-G....a.#.,d...'.'.........,.

79061000'{b

,.,,s....,,,,.

........n....,............................d.,~.............v u..s..,,,,, n,,,s s...i.. >

^. ttA' 08 tiCA a

27.Us

]w-23 Ne.f OF ~OansAC70e

__ l

/

er ts.o..~...f._.._...

...a i/..e.1 sv _

__.A C

.o..

on -

~%

(s.g 6'-

_ ep 2 Ditt 58G*==D.

l'Ipe.r /'mt[

2) DAf t $1GN
28. N A Ml QF tO7 ACilNG OFFICE 2 4. N.eal AND IlT11 Q' SlCMNE [ bf.d MAY 01193 D. J.

ugherty MAY 01 g0 prp.f /

%Wr D

? ' W/WLlF A ')) ]~

P o l *.T l'.C OF r e C( : 19 7 6. G *. ;.

c.0. I s:.

r.

TABLE OF CONTENTS

~

This Contract Consists.ut':

1.

Cover Page 2.

. Table of Contents 3.

Schedule Article I SCOPE OF WORK Article II ~

REPORTS Article III PERIOD OF PERFORMANCE

. c_

Article IV CONSIDERATION CONTRACTING OFFICER'S AUIHORIZED REPRESENTATIVE Article V Article VI

_ KEY PERSONNEL GENERAL PROVISIONS N!D MODIFICATIONS Article VII 2228 072 f

e b

Page 3

_ SCHEDULE Article I

_SCCPE OF WORV 1

Task 4 - Verification of Exxon Technique for Stability Calculations Purpose Exxon Nuclear Corporation is developing a method for predicting instabili-This method uses a version of the subchannel code ties in a BWR core.

COBRA coupled with a neutronics code to calculate the nuclear feedback.

The purpose of this task is to audit COBRA's capability to accurately predict the thermal-hydraulic aspect of the core instability calculation.

No attempt will be made to couple the COBRA code with a neutronics code.

Work Scope The paper by E. Quandt, " Analysis and Measurements of Flow Oscillations,"

1961 (copy enclosed), provides Chem. Eng. Prog. Symp. Sec., 57, 32, Ill, In these tests, experimental data for parallel channel flow oscillations.

flo.< oscillations were observed over a pressure range of 600 < PS 1600 73%.

psia and over an exit quality range of 23 < x <

This task consists of using COBRA-IV to model the test geometry and test These conditions for each of the tests described in the Quandt paper.

flux for the calculations are transient tests and the flow and/or heat should be varied as in the tests.

The principal calculatic. 21 components to be compared with the test data are:

1.

Conditions at onset of instability, Frequency of oscillations',

2.

3.

Prediction of DNB if DNB occurred in the test.

2228 073

Page 4 The use of COBRA-IV for these calculations, as opposed to other versions of COBRA, is requested because the execution time for COBRA-IV is shorter than for earlier version of COBRA when transients are calculated.

Article II - REPORTS The contractor shall submit a final report prepared in accordance with NRC Manual Chapter 3202.

The report shall contain the detailed descrip-tion of the results of the task work performed and of the models and assumptions used in the analysis.

The report shall be sub'mitted to:

M. Wayne dodges, DSS (3 copies)

2. R. Rosztoczy, DSS (1 copy)

D. J. Dougherty, Contracting Officer (1 copy)

A'Pticle III - PERIOD OF PERFORMANCE The period of performance shall be from the effective date of the contract through August 31, 1979.

Article IV - CONSIDERATION AND OBLIGATION OF FUNDS

~

A. Obligation of Funds, Estimated Cost, Fixed Fee 1)

Total funds currently available for payment and allotted to this contract is $28,739.00.

2228 074

article V - CONTRACTING OFFICER'S AUTHORIZED REPRES The following authorized representative will represent the T6virnment f the purpose of this contract:

Dr. Zoltan R. Rosztoczy (1) monitoring the The authorized representative is responsible for:

nt contractor's technical progesss, including the surveillance and assessme in of performance and recommending to the Contracting Officer changes

) performing requirements; (2). interpreting the statement of work; (3 i

technical evaluation as required; (4) performing technical inspect onsand and acceptances required by this contract;in th'e resolution of technical Within the purview of this authority, the represen t

The Contracting Officer is responsible for di rect'ing or negotiating any changes in terms, conditions, or amounts cited in the contract.-

For guidance from the authorized representative to the Contractor to (1) be consistent with the description of work set forth in this contract, (2) not constitute new assignment of work '

. be valid, it must:

or change to the expressed terms, conditions, or specifications incorporated into this c'ontract; (3) not constitute a basis for an dl extension to the period of performance or contract delivery sche u e; (4) not constitute a basis for any 17 crease in the contract ceiling amount.

2228 075

Page 6' If the Contractor receives guidance from the COAR which the Contractor feels is not valid under the criteria cited above, the Contractor shall immediately notify the COAR.

If the COAR and the Contractor are not able to resolve the question within 5 days, the Contractor shall notify the Contracting Officer.

Article VI - KEY PERSONNEL 7

In accordance with Clause No. 41 of Appendix A, the following. individuals are designated as key personnel under this contract:

Richard Kern Anthony Hsia Article VII - GENERAL PROVISIONS AND MODIFICATIONS The following General Provisions attached to Basic Ordering Agreement No.

NRC-03-78-129 02 and referenced below form a part of this contract:

Appendix A, General Provisions for Cost Type Contracts With Concerns Other

'inan toucational Institutions (2/15/78).

2228 076

.