ML19289E867

From kanterella
Jump to navigation Jump to search
RO 79-12/1P:inoperable Linear Power Range Channels. Caused by Open Connections Between Channels a & D Detector Cables.Connections Repaired
ML19289E867
Person / Time
Site: Millstone Dominion icon.png
Issue date: 05/22/1979
From: Opeka J
NORTHEAST UTILITIES
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
MP-2-4029, NUDOCS 7905290221
Download: ML19289E867 (1)


Text

NO32TH1!JUiT UTil.lTi!!!!

5 , OLTJE%','l'~

Unfrds!I. consecticur osici r T1770".'2'O ~~ 9c3) 666-6911 k e J =;;fz::?X' ::::

tiay 22,1979 MP-2 4029 Mr. Boyce H. Grier Director, Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Comission 631 Park Avenue King of Prussia, Pennsylvania 19406

Reference:

Facility Operating License No. DPR-65 Docket No. 50-336 Reportable Occurrence 50-336/79-12/1P

Dear Mr. Grier:

This letter forwards Licensee Event Report 79-12/lP, required to be submitted pursuant to the requirements of Millstone Unit 2 Appendix A Technical Specifications, Section 6.9.1.8.b.

While at 10% thermal power during the initial power ascension following a shutdown for refueling, two of the four linear power range channels were noted to be inoperable. The power ascension was halted and channel D was placed in the " bypass" condition, channel A was placed in the " tripped" condition and an investigation into the causes of the malfunctions was conducted.

Open connections were found between the channel A and D detector cables and the field wiring due to the pins being backed out at the connectors. The connections were repaired and the channels returned to service.

Any further actions as a result of subsequent investigation will be addressed'in the two week report.

Yours truly,

~

. F. Opeka Station Superintendent Millstone Nuclear Power Station JF0/ECF:llm

/Q4/ $$/