ML19289E562

From kanterella
Jump to navigation Jump to search
DG-1290 (RG 1.59 Rev 3) - Design Basis Floods for Nuclear Power Plants - Federal Register Notice
ML19289E562
Person / Time
Issue date: 02/16/2022
From: Meraj Rahimi
NRC/RES/DE/RGDB
To:
O'Donnell E
Shared Package
ML19289E458 List:
References
NRC-2022-0037, RG-1.059, Rev 3 DG-1290
Download: ML19289E562 (5)


Text

[7590-01-P]

NUCLEAR REGULATORY COMMISSION

[NRC-2022-0037]

Design-Basis Floods for Nuclear Power Plants AGENCY: Nuclear Regulatory Commission ACTION: Draft regulatory guide; request for comment.

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) is issuing for public comment a draft regulatory guide (DG), DG-1290, Design Basis Floods for Nuclear Power Plants. This DG is proposed Revision 3 of Regulatory Guide (RG) 1.59. DG-1290 proposes methods that the NRC staff considers acceptable for use in the determination of design-basis floods for nuclear power plants (NPPs).

DATES: Submit comments by April 10, 2022. Comments received after this date will be considered if it is practical to do so, but the NRC is able to ensure consideration only for comments received on or before this date.

ADDRESSES: You may submit comments by any of the following methods, however, the NRC encourages electronic comment submission through the Federal rulemaking website:

Federal Rulemaking Website: Go to https://www.regulations.gov and search for Docket ID NRC-2022-0037. Address questions about Docket IDs in Regulations.gov to Stacy Schumann; telephone: 301-415-0624; email:

Stacy.Schumann@nrc.gov. For technical questions, contact the individuals listed in the For Further Information Contact section of this document.

Mail comments to: Office of Administration, Mail Stop: TWFN-7-A60M, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001, ATTN: Program Management, Announcements, and Editing Staff.

2 For additional direction on obtaining information and submitting comments, see Obtaining Information and Submitting Comments in the SUPPLEMENTARY INFORMATION section of this document.

FOR FURTHER INFORMATION CONTACT: Joseph Kanney, telephone: 301-415-1920, email: Joseph.Kanney@nrc.gov and, Edward ODonnell, telephone: 301-415-3317, email: Edward.ODonnell@nrc.gov. Both are staff members of the Office of Nuclear Regulatory Research, at the U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001.

SUPPLEMENTARY INFORMATION:

I. Obtaining Information and Submitting Comments A. Obtaining Information Please refer to Docket ID NRC-2022-0037 when contacting the NRC about the availability of information for this action. You may obtain publicly available information related to this action by any of the following methods:

Federal Rulemaking Website: Go to https://www.regulations.gov and search for Docket ID NRC-2022-0037.

NRCs Agencywide Documents Access and Management System (ADAMS): You may obtain publicly available documents online in the ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by email to PDR.Resource@nrc.gov. DG-1290, Design-Basis Floods for Nuclear Power Plants is available in ADAMS under Accession No. ML19289E561.

NRCs PDR: You may examine and purchase copies of public documents, by appointment, at the NRCs PDR, Room P1 B35, One White Flint North, 11555

3 Rockville Pike, Rockville, Maryland 20852. To make an appointment to visit the PDR, please send an email to PDR.Resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8:00 a.m. and 4:00 p.m. (ET), Monday through Friday, except Federal holidays.

B. Submitting Comments The NRC encourages electronic comment submission through the Federal rulemaking website (https://www.regulations.gov). Please include Docket ID NRC-2022-0037 in your comment submission.

The NRC cautions you not to include identifying or contact information that you do not want to be publicly disclosed in your comment submission. The NRC will post all comment submissions at https://www.regulations.gov as well as enter the comment submissions into ADAMS. The NRC does not routinely edit comment submissions to remove identifying or contact information.

If you are requesting or aggregating comments from other persons for submission to the NRC, then you should inform those persons not to include identifying or contact information that they do not want to be publicly disclosed in their comment submission. Your request should state that the NRC does not routinely edit comment submissions to remove such information before making the comment submissions available to the public or entering the comment into ADAMS.

II. Additional Information The NRC is issuing for public comment a DG in the NRCs Regulatory Guide series. This series was developed to describe methods that are acceptable to the NRC staff for implementing specific parts of the agencys regulations, to explain techniques that the staff uses in evaluating specific issues or postulated events, and to describe information that the staff needs in its review of applications for permits and licenses.

4 The DG, entitled, Design-Basis Floods for Nuclear Power Plants is proposed Revision 3 of RG 1.59, which is temporarily identified by its task number, DG-1290. It proposes methods that the NRC staff considers acceptable for use in the determination of design-basis floods for NPPs.

The staff is also issuing for public comment a draft regulatory analysis for revision of RG 1.59 (ML12121A020). The staff developed a regulatory analysis to assess the value of issuing or revising a regulatory guide as well as alternative courses of action.

III. Backfitting, Forward Fitting, and Issue Finality Issuance of DG-1290, if finalized, would not constitute backfitting as that term is defined in section 50.109 of title 10 of the Code of Federal Regulations (10 CFR),

Backfitting, and as described in NRC Management Directive (MD) 8.4, Management of Backfitting, Forward Fitting, Issue Finality, and Information Requests; constitute forward fitting as that term is defined and described in MD 8.4; or affect issue finality of any approval issued under 10 CFR part 52, Licenses, Certificates, and Approvals for Nuclear Power Plants. As explained in DG-1290, applicants and licensees are not required to comply with the positions set forth in DG-1290.

IV. Submitting Suggestions for Improvement of Regulatory Guides A member of the public may, at any time, submit suggestions to the NRC for improvement of existing RGs or for the development of new RGs. Suggestions can be submitted on the NRCs public website at https://www.nrc.gov/reading-rm/doc-collections/reg-guides/contactus.html. Suggestions will be considered in future updates and enhancements to the Regulatory Guide series.

Dated: February 16, 2022.

5 For the Nuclear Regulatory Commission.

/RA/

Meraj Rahimi, Chief, Regulatory Guide and Programs Management Branch, Division of Engineering, Office of Nuclear Regulatory Research.