| | | Reporting criterion |
|---|
| 05000338/LER-1978-026, Forwards LER 78-026/99X-1 & 78-089/03X-1 | Forwards LER 78-026/99X-1 & 78-089/03X-1 | |
| 05000338/LER-1978-026-99, /99X-1 on 780413:with All Rods Out at Beginning of Core Life,Hot Zero Pwr Moderator Temp Coefficient Revealed It Was More Positive than 0 Delta K/K/F in Tech Spec,Due to Positive Mtc for the all-rods-out Configuration | /99X-1 on 780413:with All Rods Out at Beginning of Core Life,Hot Zero Pwr Moderator Temp Coefficient Revealed It Was More Positive than 0 Delta K/K/F in Tech Spec,Due to Positive Mtc for the all-rods-out Configuration | |
| 05000338/LER-1978-051, Forwards LER 78-051/01X-1 | Forwards LER 78-051/01X-1 | |
| 05000338/LER-1978-051-01, /01X-1 on 780614:auxiliary Feedwater Pump start-up Delay Due to Improper Adjustment of Instantaneous Contracts on an Aquastat 2400 Series Relay | /01X-1 on 780614:auxiliary Feedwater Pump start-up Delay Due to Improper Adjustment of Instantaneous Contracts on an Aquastat 2400 Series Relay | |
| 05000338/LER-1978-053, Forwards Addl Info Re LER 78-053/01T-0 Forwarded on 780706 Which Reported Temporary Inoperability of Diesel Driven Fire Pump.Diesel Engine Was Replaced & New Engine Tested Per Maint Procedures & Declared Operable on 780702 | Forwards Addl Info Re LER 78-053/01T-0 Forwarded on 780706 Which Reported Temporary Inoperability of Diesel Driven Fire Pump.Diesel Engine Was Replaced & New Engine Tested Per Maint Procedures & Declared Operable on 780702 | |
| 05000338/LER-1978-061, Forwards LER 78-061/99X-1 & 78-089/03L-0 | Forwards LER 78-061/99X-1 & 78-089/03L-0 | |
| 05000338/LER-1978-061-99, /99X-1 on 780712:the Area Temp Monitoring Log Erroneously Recorded Excessive Temps in Battery Rooms.Cause Is Unknown | /99X-1 on 780712:the Area Temp Monitoring Log Erroneously Recorded Excessive Temps in Battery Rooms.Cause Is Unknown | |
| 05000338/LER-1978-063-03, /03X-1 on 780728:particulate Filter & Charcoal Filter Were Clogged.Caused by Driving Mechanism of RM-RMS-159 Filter Being Jammed | /03X-1 on 780728:particulate Filter & Charcoal Filter Were Clogged.Caused by Driving Mechanism of RM-RMS-159 Filter Being Jammed | |
| 05000338/LER-1978-063, Forwards LER 78-063/03X-1 | Forwards LER 78-063/03X-1 | |
| 05000338/LER-1978-080-03, /03X-1 on 780815: Unidentified Reactor Coolant Leak of 1.93 Gpm Detected & Repaired,But Deviation Rept & LER Were Not Submitted | /03X-1 on 780815: Unidentified Reactor Coolant Leak of 1.93 Gpm Detected & Repaired,But Deviation Rept & LER Were Not Submitted | |
| 05000338/LER-1978-085-03, /03L-0 on 780830:Testing of Quench Spray Pump 1-QS-P-1B Showed Pressure Drop of Over 10psi on the Suction Line During Oper,Caused by Wooden Dam in Piping. (Encl to 7810030071) | /03L-0 on 780830:Testing of Quench Spray Pump 1-QS-P-1B Showed Pressure Drop of Over 10psi on the Suction Line During Oper,Caused by Wooden Dam in Piping. (Encl to 7810030071) | |
| 05000338/LER-1978-089-03, /03X-1 on 780915:during Periodic Test,A Bistable (FC-1485 in Protec Channel Iv)Associated W/Hi Steamline Flow S.I.Actuation Failed to Trip,Due to Defective Bistable Card | /03X-1 on 780915:during Periodic Test,A Bistable (FC-1485 in Protec Channel Iv)Associated W/Hi Steamline Flow S.I.Actuation Failed to Trip,Due to Defective Bistable Card | |
| 05000338/LER-1978-090, Forwards LER 78-090/03L-0 | Forwards LER 78-090/03L-0 | |
| 05000338/LER-1978-090-03, /03L-0:on 780919,during Critical steady-state Operation,Axial Flux Difference Deviated Greater than -5% from Target.Caused by Rapid Load Reduction Necessitated by Clogging of Condensate Pump Strainer | /03L-0:on 780919,during Critical steady-state Operation,Axial Flux Difference Deviated Greater than -5% from Target.Caused by Rapid Load Reduction Necessitated by Clogging of Condensate Pump Strainer | |
| 05000338/LER-1978-091, Forwards LER 78-091/03L-0,LER 78-092/03L-0,LER 78-094/03L-0, LER 78-095/03L-0,LER 78-096/03L-0,LER 78-097/03L-0, LER 78-099/03L-0 & LER 78-103/03L-0 | Forwards LER 78-091/03L-0,LER 78-092/03L-0,LER 78-094/03L-0, LER 78-095/03L-0,LER 78-096/03L-0,LER 78-097/03L-0, LER 78-099/03L-0 & LER 78-103/03L-0 | |
| 05000338/LER-1978-091-03, /03L-0:on 780927,nonconservative Low Flow Trip Setpoint Discerned During Routine Recalibr of Reactor Coolant Flow Loop Channel B.Caused by Procedural Error.Loop Calibr Corrected | /03L-0:on 780927,nonconservative Low Flow Trip Setpoint Discerned During Routine Recalibr of Reactor Coolant Flow Loop Channel B.Caused by Procedural Error.Loop Calibr Corrected | |
| 05000338/LER-1978-092-03, /03L-0:on 780927,transmitter LT1486 Did Not Activate hi-hi Level Turbine Trip & Feedwater Isolation Until Level of 76.33% Reached in Violation of Tech Spec Limit.Caused by Drift in Transmitter Output | /03L-0:on 780927,transmitter LT1486 Did Not Activate hi-hi Level Turbine Trip & Feedwater Isolation Until Level of 76.33% Reached in Violation of Tech Spec Limit.Caused by Drift in Transmitter Output | |
| 05000338/LER-1978-093-03, /03L-0:on 781017,multiplier Divider Card Output Drifted So That steam-feedwater Flow Mismatch Would Not Trip Until Actual Value of 1,932,000 Lbs Per Hour Occurred.Caused by Electronic Drift in Card.Card Recalibr | /03L-0:on 781017,multiplier Divider Card Output Drifted So That steam-feedwater Flow Mismatch Would Not Trip Until Actual Value of 1,932,000 Lbs Per Hour Occurred.Caused by Electronic Drift in Card.Card Recalibr | |
| 05000338/LER-1978-094-03, /03L-0:on 780927,containment Isolation Valves TV- CC-102D & TV-CC-102F Failed to Close During Cycling.Caused by Blocked Solenoid Air Supply | /03L-0:on 780927,containment Isolation Valves TV- CC-102D & TV-CC-102F Failed to Close During Cycling.Caused by Blocked Solenoid Air Supply | |
| 05000338/LER-1978-095-03, /03L-0:on 780928,during Routine Recalibr,High Pressure Reactor Trip Bistable Would Not Activate Until Actual Pressure of 2,396 Psig Reached.Caused by Transmitter Output Drift | /03L-0:on 780928,during Routine Recalibr,High Pressure Reactor Trip Bistable Would Not Activate Until Actual Pressure of 2,396 Psig Reached.Caused by Transmitter Output Drift | |
| 05000338/LER-1978-096-03, /03L-0:on 780927,fluid Lost in Snubber 1-RC-HSS-861.Caused by Leak at Reservoir Seal | /03L-0:on 780927,fluid Lost in Snubber 1-RC-HSS-861.Caused by Leak at Reservoir Seal | |
| 05000338/LER-1978-097-03, /03L-0:on 780928,fluid Lost in Snubber 1-RC-HSS-873.Caused by Warping of Reservoir from Steam Generator Insulation on Blanket | /03L-0:on 780928,fluid Lost in Snubber 1-RC-HSS-873.Caused by Warping of Reservoir from Steam Generator Insulation on Blanket | |
| 05000338/LER-1978-098-01, /01T-0:on 781004,nonconservatism Noted in Calculations Performed on Axial Power Distribution Monitoring Sys.Caused by Data Value round-off | /01T-0:on 781004,nonconservatism Noted in Calculations Performed on Axial Power Distribution Monitoring Sys.Caused by Data Value round-off | |
| 05000338/LER-1978-098, Forwards LER 78-098/01T-0 | Forwards LER 78-098/01T-0 | |
| 05000338/LER-1978-099-03, /03L-0:on 780926,during Mode 5 Operatio,Level Transmitter LT-1475 Did Not Activate hi-hi Level Turbine Trip & Feedwater Isolation Bistable Until Actual Level of 76.82 Reached.Caused by Transmitter Output Drift | /03L-0:on 780926,during Mode 5 Operatio,Level Transmitter LT-1475 Did Not Activate hi-hi Level Turbine Trip & Feedwater Isolation Bistable Until Actual Level of 76.82 Reached.Caused by Transmitter Output Drift | |
| 05000338/LER-1978-100, Forwards LER 78-100/01X-0, 78-110/03L-0 & 78-113/03L-0 | Forwards LER 78-100/01X-0, 78-110/03L-0 & 78-113/03L-0 | |
| 05000338/LER-1978-100-01, /01X-0 on 781108:a Field Mod Was Made to Vessel Lower Head Insulation & the Mod Was Not Seismically Analyzed IAW FSAR Due to Personnel Error.Subsequently Analyzed by Stone & Webster & by Westinghouse | /01X-0 on 781108:a Field Mod Was Made to Vessel Lower Head Insulation & the Mod Was Not Seismically Analyzed IAW FSAR Due to Personnel Error.Subsequently Analyzed by Stone & Webster & by Westinghouse | |
| 05000338/LER-1978-101-03, /03L-0:on 781002,during Mode 3 operation,power- Range Detector N-44 Placed in Trip Mode Until Detector Calibr.Caused by Detector Replacement | /03L-0:on 781002,during Mode 3 operation,power- Range Detector N-44 Placed in Trip Mode Until Detector Calibr.Caused by Detector Replacement | |
| 05000338/LER-1978-102-03, /03L-0:on 781002,during Mode 3 Operation,Channel 3 of Steam Generator Level Indicator LI-1496 Tripped.Caused by Leak on Manifold Gasket Below Level Transmitter Resulting in Low Reading | /03L-0:on 781002,during Mode 3 Operation,Channel 3 of Steam Generator Level Indicator LI-1496 Tripped.Caused by Leak on Manifold Gasket Below Level Transmitter Resulting in Low Reading | |
| 05000338/LER-1978-103-03, /03L-0:on 781004,during Heatup from Hot Shutdown to Hot Standby,Feedwater Line from Ecst 1-CN-TK-1 to Steam Generators A,B & C Via 1-FW-P-3B Auxiliary Feedwater Pumps Not Secured.Caused by Unavailability of Plant 2d | /03L-0:on 781004,during Heatup from Hot Shutdown to Hot Standby,Feedwater Line from Ecst 1-CN-TK-1 to Steam Generators A,B & C Via 1-FW-P-3B Auxiliary Feedwater Pumps Not Secured.Caused by Unavailability of Plant 2d | |
| 05000338/LER-1978-104-03, /03L-0:on 781009,during Mode 1,leak Detected in Steam Valve 1-MS-120 Valve Leads to Steam Generator Auxiliary Feedwater Pump 1-FW-P-2.Caused by Isolation of Steamline,Causing Pump Inoperability | /03L-0:on 781009,during Mode 1,leak Detected in Steam Valve 1-MS-120 Valve Leads to Steam Generator Auxiliary Feedwater Pump 1-FW-P-2.Caused by Isolation of Steamline,Causing Pump Inoperability | |
| 05000338/LER-1978-105-03, /03L-0:on 781010,axial Flux Difference Deviated Greater than 5%.Caused by Rapid Load Reduction Necessitated by Problems W/Condenser Circulating Water Valve | /03L-0:on 781010,axial Flux Difference Deviated Greater than 5%.Caused by Rapid Load Reduction Necessitated by Problems W/Condenser Circulating Water Valve | |
| 05000338/LER-1978-106-03, /03L-0:on 781010,power-range Instrumentation Channel N-41 Taken Out of Svc to Facilitate Replacement of Faulty Gain Pot.Caused by Dirt in Potentiometer,Resulting in Erratic Gain | /03L-0:on 781010,power-range Instrumentation Channel N-41 Taken Out of Svc to Facilitate Replacement of Faulty Gain Pot.Caused by Dirt in Potentiometer,Resulting in Erratic Gain | |
| 05000338/LER-1978-107-03, /03L-0:on 781005,during Full Power Operation, Containment Atmosphere & Gas Monitoring Sys Inoperable.On 781005,breaker to Containment Atmosphere Particulate & Gas Monitoring Pump Opened,Cutting Power to Sys | /03L-0:on 781005,during Full Power Operation, Containment Atmosphere & Gas Monitoring Sys Inoperable.On 781005,breaker to Containment Atmosphere Particulate & Gas Monitoring Pump Opened,Cutting Power to Sys | |
| 05000338/LER-1978-107, Forwards LER 78-107/03L-0,LER 78-108/03L-0 & LER 78-109/03L-0 | Forwards LER 78-107/03L-0,LER 78-108/03L-0 & LER 78-109/03L-0 | |
| 05000338/LER-1978-108-03, /03X-1 on 781012:during Mode 1 Opers,At 100% Pwr, Feedwater Flow Transmitter FT-1496 on Feedwater Loop C Failed Low.Caused by Blown Fuse.Fuse Subsequently Replaced | /03X-1 on 781012:during Mode 1 Opers,At 100% Pwr, Feedwater Flow Transmitter FT-1496 on Feedwater Loop C Failed Low.Caused by Blown Fuse.Fuse Subsequently Replaced | |
| 05000338/LER-1978-108, Forwards LER 78-108/03X-1 | Forwards LER 78-108/03X-1 | |
| 05000338/LER-1978-109-03, /03L-0:on 781011,during Functional Test on Containment Hydrogen Recombiner 2-HC-HC-1,heater Gas Temp Failed to Reach Greater than 700 F.Caused by Operator Selecting Improper Control Settings | /03L-0:on 781011,during Functional Test on Containment Hydrogen Recombiner 2-HC-HC-1,heater Gas Temp Failed to Reach Greater than 700 F.Caused by Operator Selecting Improper Control Settings | |
| 05000338/LER-1978-110-03, /03l-0 on 781024:following a Reactor Trip,The Containment Bulk Avg Temp Exceeded 105 Degrees F Tech Spec Limit Due to Steam Loss to Chilled Water Sys Vacuum Refrigeration Unit | /03l-0 on 781024:following a Reactor Trip,The Containment Bulk Avg Temp Exceeded 105 Degrees F Tech Spec Limit Due to Steam Loss to Chilled Water Sys Vacuum Refrigeration Unit | |
| 05000338/LER-1978-111-01, /01T-0:on 781025,nonseismically Qualified Instantaneous Contacts & Agastat Timers Used in Control Circuits for MOV-QS-102A & MOV-QS-102B.Control Circuit Will Be Modified by Design Change | /01T-0:on 781025,nonseismically Qualified Instantaneous Contacts & Agastat Timers Used in Control Circuits for MOV-QS-102A & MOV-QS-102B.Control Circuit Will Be Modified by Design Change | |
| 05000338/LER-1978-111, Forwards LER 78-111/01T | Forwards LER 78-111/01T | |
| 05000338/LER-1978-112-03, /03L-0 on 781025:During Routine Startup Oper,Axial Flux Difference Deviated Greater than 5% from target.48 Penalty Min Accumulated.Caused by Xenon Transient Occurrence.Corrective Action:Boration by Reactor Operator | /03L-0 on 781025:During Routine Startup Oper,Axial Flux Difference Deviated Greater than 5% from target.48 Penalty Min Accumulated.Caused by Xenon Transient Occurrence.Corrective Action:Boration by Reactor Operator | |
| 05000338/LER-1978-112, Forwards LER 78-112/03L-0 | Forwards LER 78-112/03L-0 | |
| 05000338/LER-1978-113-03, /03l-0 on 780927:after maint,TV-BD100A,B,D & F Were Tested But Not Timed Prior to Return to Svc,Due to Personnel Error.Personnel Have Reviewed the Requirements | /03l-0 on 780927:after maint,TV-BD100A,B,D & F Were Tested But Not Timed Prior to Return to Svc,Due to Personnel Error.Personnel Have Reviewed the Requirements | |
| 05000338/LER-1978-114-03, /03L-0 on 781101:axial Flux Difference Deviated Greater than -5% from Target for One Minute.Caused by Pwr Reduction Necessitated by Problem with Cooling Fans on Main Station Transformer C | /03L-0 on 781101:axial Flux Difference Deviated Greater than -5% from Target for One Minute.Caused by Pwr Reduction Necessitated by Problem with Cooling Fans on Main Station Transformer C | |
| 05000338/LER-1978-114, Forwards LER 78-114/03L-0,78-115/03L-0,78-116/03L-0 & 78-117/03L-0 | Forwards LER 78-114/03L-0,78-115/03L-0,78-116/03L-0 & 78-117/03L-0 | |
| 05000338/LER-1978-115-03, /03L-0 on 781107:during 1-pt-134 Periodic Test, MOV-QS102A Would Not Return to Normal Closed Position Because of Dirty Contacts on Valves Torgue Switch.Contacts Were Cleaned | /03L-0 on 781107:during 1-pt-134 Periodic Test, MOV-QS102A Would Not Return to Normal Closed Position Because of Dirty Contacts on Valves Torgue Switch.Contacts Were Cleaned | |
| 05000338/LER-1978-116-03, /03L-0 on 781102:during Pwr Escalation,Upper Flux Deviation Alarm Was Received & Traced to a High Quadrant Pwr Tilt Ratio.Believed Cause Was Nonlinear Detector Resonse at Lower Pwr | /03L-0 on 781102:during Pwr Escalation,Upper Flux Deviation Alarm Was Received & Traced to a High Quadrant Pwr Tilt Ratio.Believed Cause Was Nonlinear Detector Resonse at Lower Pwr | |
| 05000338/LER-1978-117-03, /03L-0 on 781101:main Steam Trip Valve 1-TV-MS-111A Was Detected Leaking Due to a Deteriorated Internal Gasket.Valve Was Isolated & Gasket Replaced | /03L-0 on 781101:main Steam Trip Valve 1-TV-MS-111A Was Detected Leaking Due to a Deteriorated Internal Gasket.Valve Was Isolated & Gasket Replaced | |
| 05000338/LER-1978-118, Forwards LER 78-118/99T-0 | Forwards LER 78-118/99T-0 | |