ML19289C158
| ML19289C158 | |
| Person / Time | |
|---|---|
| Site: | Yellow Creek, Black Fox |
| Issue date: | 11/27/1978 |
| From: | Gallo J ISHAM, LINCOLN & BEALE |
| To: | Purdom P, Shon F, Wolfe S DREXEL UNIV., PHILADELPHIA, PA, Atomic Safety and Licensing Board Panel |
| References | |
| NUDOCS 7812140285 | |
| Download: ML19289C158 (3) | |
Text
,
NRC FUDLIC DCCUENT ROOM cu ISHAM, LINCOLN & BEALE
/
D COUNSELORS AT LAW g
SOSO 87T STR EET, N. W. SEvCNTH FLOOR waS HI N G T ON, 0. C. 2 OO 3 6
- t.
y+
T ELEPHON E 202-833-9730
, [E,"g I
t 5,
os c r."ast warional Plaza
,4..*y ronry-SEcoNO rLoOR d'"
c-ic co,eLunois eoso3 ff g g
rcLcraoNE 3I2-786-7500 Qq TE LC x. 2-52 8 8 November 27, 1978 a
g a)
Sheldon J. Wolfe, Esquire Mr. Frederick J.
Shon, Member Atomic Safety and Licensing Atomic Safety and Licensing Board Panel Board Panel U.S.
Nuclear Regulatory U.S. haclear Regulatory Commission Commisd on Washington, D.
C.
20555 Washington, D. C.
20555 Dr. Paul W.
Purdom, Director Environmental Studies Group Drexel University 32nd and Chestnut Streets Philadelphai, Pennsylvania 19104 Re:
In the Matter of the Application of
)
Public Service Company of Oklahoma,
)
Associated Electric Cooperative, Inc.
) Docket No. STN 50-556 and
)
STN 50-557 Western Farmers Electric Cooperative
)
)
(Black Fox Station, Units 1 and 2)
)
Gentlemen:
I am enclosing Amendment 13 to the PSAR for the Black Fox Station.
Applicants intend to offer Amendment 13 into evidence at the upcoming hearings immediately after the completion the rebuttal testimony by Mr. Aaron Levine.
Appli-cants also intend to introduce page 3.8-45c into evidence.
This page was inadvertently omitted from Amendment 12.
Counsel for the parties have agreed to the follow-ing order of issues for the December hearings:
a.
Completion of the ECCS issues,
-i.e.,
Questions 2-1, 2-2 and 2-3.
b.
Fire Protection, i.e., Contentions 7, 8 and 9.
c.
Post Accident Monitoring, i.e.,
Question 13-1.
7812140 W
. d.
- ATWS, i.e., Contention 67.
e.
Completion of QA-Special Processes, i.e., Question 10-4.
Items a. b. and c. should occupy the first week's hearingr
-- December 5-8.
Item d.
should consume December 11 and 12.
Item e. can be taken up after oral argument on December 13.
No agreement has been reached on issues to be taken up on December 14 and 15.
By copy of this letter, I am requesting Mr. Farris to redouble his efforts to be prepared to litigate additional issues so that December 14 and 15 can be fruit-fully utilized as hearing days.
With respect to Contentions 8, 9 and 10 - Fire Protection, Applicants intend tc call two sets of witnesses.
Messrs. Gang and Johnson will testify and then be available for cross-examination on the GE scope of supply (the PGCC) with respect to Contentions 7 and 8.
Thereafter, Mr. Engmann and Dr. Cox will testify on the Black & Veatch scope of supply and then be available for cross-examination.
You will recall that Applicants' witness on Ques-tion 10-4, Mr. Long, became ill and he was unable to testify.
Mr. Long's illness continues to prevent his appearance in this proceeding.
Applicants now intend to sponsor the Long testimony through Messrs. William Gang and Lee Marquis.
These witnesses will be prepared to adopt the Long testimony as their own on December 13.
Sincerely, Joseph Gallo One of the Attorneys for the Applicants JG/kar cy:
T.
F.
Engelhardt by delivery L.
Dow Davis by delivery William Paton by delivery Colleen Woodhead by delivery Joseph Farris by Federal Express John Woodard by Federal Express Balance of Service List by Mail (Amendment 13 sent under separate cover)
s.-
.- m
=~~~ ~~.u = -; -
...;......r..
. -I BFS i
r/l Abnormal / extreme environmental conditions
{...
3 I'.,.f The Strength Design method shall be ueed and the following
]
s load combinations shall be satisfied:
I 3
(iv)
U=D+L+T
+R
+H+B O
O y
.j i
d (v)
U=D+L+T
+R
+ H + Feqs o
o g
( w-a i
12
- (v )
U=D+L+H2 + Feqs y..,.--t
['
' };
(vi)
U=D+L+T
+R
+H o
o y
5 (vii)
U=D+L+T 8-Ro+H+Wt o
t l
~
- (vii ) U = D + L + H2+N u
t n'- "'d (viii) U = D + L + T
+R
+ 1.5 P
+H 3
a a
a j+Y)
(ix)
U=D+L+T
+R
+ 1.25 P + H + 1.25 Fego +(Y
+Y r
m 3,
t a
a a
a i.
k (x)
U=D+L+T
+R
+P
+ H + Fegs + (Y
+Y j+Y) a a
a r
m
)
s
(;
s';
Both cases of L having itt full value or being completely absent
.v
. l, shall be considered.
.m<d
- Note: These loading combinations are applicable as a station shutdown condition and apply only to the design of the 12 exterior subgrade walls of the structures.
5^" 7 3.8.4.2.3.3 Load Combinations for Steel Members s
- 3
',s'
- ]
Either the elasitic working stress design c.ethods of Part i n' AISC, or
,q
- 3. s
' /.;
the plastic design methods of Part 2 of AISC, may be used.
1
?
3 a)
If the elastic working stress design methods are used:
s
- t. -
,3 b, '";.s}
(1)
S=D+L s
a
[.
".;)
(ii)
S = D + L + Fego s
,s (iii)
S=D+L+W s
s 1:
If thermal stresses due to T and R are present and are secondary and self-limiting in nature, the following combinations should also
')
be satisfied:
- t
, ~ '.. ;
(1)a 1.5 S = D + L + T,+ R, s
s
'M
'q. ',' '.^q
- /;
31'ho.-al 3.8-45c 12-100678