ML19284A463
| ML19284A463 | |
| Person / Time | |
|---|---|
| Site: | Prairie Island |
| Issue date: | 01/09/1979 |
| From: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | |
| Shared Package | |
| ML19284A461 | List: |
| References | |
| 50-306-78-21, NUDOCS 7903060505 | |
| Download: ML19284A463 (1) | |
Text
.
Appendix A ll)
NOTICE OF VIOLATION Northtrn States Power Docket No. 50-306 Company Based on the results of the NRC inspection con (acted on November 28 and 29, December 5 and 6,1978, it appears that certain of your activities were not conducted in full compliance with NRC require-ments as noted below.
The item below is a deficiency.
10 CFR Part 50, Appendix B, Criteria IX, states in part that " Measures shall be established to assure that special processes including welding.
. and nondestructive testing.
. are controlled ar.d accom-plished.
.with... applicable specifications.
.and other special requirements.
The Prairie Island Nuclear Generating Plant FSAR, Section 1.8 commits to 10 CFR Part 50, Appendix B.
a.
Paragraph 8.6.4 SNT-TC-1A, 1975 Edition requires that a com-posite grade of 90% is necessary to pass the test.
Contrary to the above, Lambert, MacGill, Thomas, Inc. procedure No. QA-6, Revision 6, " Qualification and Certification of NDE Personnel", >brch 6,1978, did not state that for NDE Level III personnel, a composite grade of 90% is required to pass the test.
b.
Lambert, FbcGill, Thomas, Inc. Procedure No. QA-6, Revision 6, March '
1978, " Qualification and Certification of NDE Personnel,"
SNT-TC-1A, 1975 Edition, requires experience prior to taking an examination for any NDE method.
Contrary to the above, two NDE personnel certifications received did not document previous NDE experience.
79030605o6