liMHil'HI!A!iT UTII.ITII!!i
.a ;
- s u r. <, r sm, u u.:n s <
p a g ox gyn
).b((- '.,$((M C c 7'.n.,
HARTFORD, CONNECTICUT 06101 (203) 666-6911
,,s
,, sn
,m L
L A
- ";,, 'l 'l,. ' 'l,
February 28, 1979 Docket Nos. 50-245 50-336 Director of Nuclear Reactor Repilation Attn:
Mr. D. L. Ziemann, Chief Operating Reactors Branch #2 Mr. R. Reid, Chief Operating Reactors Branch #4 U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Gentlemen:
Millstone Nuclear Power Station, Unit Nos.1 and 2 Proposed Revisions to the Technical Specifications Pursuant to 10CFR50.90, Northeast Nuclear Energy Company (NNECO) hereby proposes to amend its operating licenses, DPR-21 and DPR-65, by incorporating the attached changes into the Technical Specifications for Millstone Unit Nos.1 and 2.
These Specifications are administrative in nature and reflect recent organiza-tional changes within NNECO. These proposed changes include a revised facility organizational diagram and a clarification of members of the Plant Operations Review Committee (PORC). Only one set of revised pages are provided, as the Section 6 Technical Specifications for the two units are essentially identical.
A technical review of these specifications has found them to be acceptable; a safety evaluation has also been performed in accordance with 10CFR50.59 and has concluded that these changes do not constitute any unreviewed safety questions.
The Millstone Site Nuclear Review Board has reviewed and approved the proposed changes and has concurred with the above determination.
NNECO has reviewed the above proposed license amendment pursuant to the require-ments of 10CFR170 and has determined that the proposal constitutes a combination Class II and Class I amendment. Accordingly, enclosed herewith is payment in the amount of $1,600 (one thousand six hundred dollars). The basis for this determina-7903080 N/9
. tion is that the proposal involves changes that are administrative in nature and have no safety or en*vironmental significance, and, in addition, involve a duplicate amendment request for another unit at the same site.
Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY TP}%L W. G. Counsil Vice President Attachment e
STATE OF CONNECTICUT )
)
ss. Berlin M8 # M COUNTY OF HARTFORD
)
j Then personally appeared before me W. G. Counsil, who being duly sworn, did state that he is Vice President of dortheast Nuclear Energy Company, a Licensee herein, that he is authorized to execute and file the foregoing information in the name and on behalf of the Licensees herein and that the statements contained in said information are true and correct to the best of his knowledge and belief.
J h h&
(
My Commission Expires March 31,19 Notary Public
DOCKET NOS. 50-245 50-336 ATTACHMENT MILLSTONE NUCLEAR POWER STATION, UNIT NOS.1 AND 2 PROPOSED CHANGES TO THE TECHNICAL SPECIFICATIONS FEBRUARY, 1979
A S ta t ion
- SORC Superin te nd ent
\\dministrative S ta f f s ta ti on Unit 1 Unit 2 Unit 3 PORC g, y,,
Superintendent Superintendent Superintendent Superintendent Same Organization u
i'o As Unit 1 statt__
Training Supervisor I&C Operations Engineerint 3aintenance QA Supervisor Supervisor Supervisor Supervisor
-lupervisor Security Supervisor llealth Physics Supervisor Chemistry Supervisor LSO Other Site Support Services j'
Shift W
Supervisor Lo Supe rvising Reactor Control Engineers 7:n ei n ee r
,g-ernrnra YO Control Operators Plant Equipment Onerators CODE: LO Licensed Operator LSO Licensed Senior Operator
- Overall Site Responsibility for fire protection.
FIGURE 6.2-2 FACILITY ORGANIZATION - MILLSTONE NUCLEAR POWER STATION
ADMINISTRATIVE CONTROLS 6.4 TRAINING 6.4.1 A retraining and replacement training program for the facility staff shall be maintained under the direction of the Station Suoerintendent and shall meet or exceed the requirements and reconnendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55.
6.4.2 A training program for the Fire Brigade shall be maintained under the direction of the Training Supervisor and shall meet or exceed the requirementsofSection27oftheNFPACode-1976,except)hatFire Brigade training sessions shall be held at least quarterly.
6.5 REVIEW AND AUDIT 6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)
FUNCTION
- 6. 5.1.1 The PORC shal.1 function to advise the Unit Superintendent on all matters related to nuclear safety.
COMPOSITION 6.5.1.2 The PORC shall be composed of the:
Chairman:
Unit Superintendent Vice Chairman
& Member:
Operations Supervisor Hernber:
Maintenance Supervisor Member:
Instrument and Control Supervisor Member:
Reactor Engineer Member:
Encineerina Supervisor or Startuo Sunervisor*
l Member.:
Chemistry Supervisor or Station Services Superintendent or General Services Supervisor l
or Health Physics Supervisor Member:
Staff Engineer
- ALTERNATES 6.5.1.3 Alternate members shall be appointed in writing by the PORC Chaimar, to serve on a temporary basis; however, no more than two alternates shall part:1pate in PORC activities at any one time.
- When position is staffed.
- The Staff Engineer member of the PORC shall have an academic degree in engineering or physical science field; and in addition, shall have a minimum of five years technical experience, of which a minimum of three years shall be in the nuclear power plant industry.
- o be effective by March 1,1978.
T AmendmentNo.H,33,JE,34,M 6-5