ML19282D675

From kanterella
Jump to navigation Jump to search
Forwards IE Bulletin 79-19, Packaging of Low Level Radwaste for Transport & Burial. Written Response Required
ML19282D675
Person / Time
Issue date: 08/10/1979
From: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
CARDINAL SURVEYS
Shared Package
ML19282D676 List:
References
NUDOCS 8008180531
Download: ML19282D675 (1)


Text

' lL g

Ilt.l i1 is :.11 1 l '.

E' 7 '.

r;tJCI ! Alt lif GUl_ AT Ol{ Y CO'. T.11','; ION d

c n;, a. 'W -

z sa r,to';tv t, S...;. ps

[

f.11 si v A N i t t./ t. ra n iv t, '.u t f ( 1000 a,,

j i.n urt.trm n ya no n

....+

August 10, 1979 f

~ '

C/

t t.AHUI,NAL Suwv YS CUMPANY UutSSA

~ u F e n u v i E. n c2d ::iUUir1 IX 74761 Cent 1ccen:

Enclosed is IF. Eulletin No. 79-19, which requires ac:ica by you with regard to your NRC license.

Should you have questions regarding this Eulletin or the actions required of you, please contact this office.

Sincerely, 11 2

l U

~

&E g.fkunlM Karl V. Seyfru f!

Director

Enclosures:

1.

IE Eulletin No. 79-19 2.

List of Bulletins Issued in Last Si. >!ont hs 8008180 N !

I t

UNITED STATES NUCLEAR REGUL1 TORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 IE Bulletin No. 79-19 Date:

August 10, 1979 Page 1 of 3 PACKAGING 0F LOW-LEVEL RADI0 ACTIVE WASTE FOR TRANSPORT AND BURIAL Description of Circumstances:

Low-level radioactive waste is that waste which can be transferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of Nevada, South Carolina, and Washington. On July 10, 1979, the Governors of the three states notified NRC Chairman Hendrie of the serious and repeated disregard for rules governing the shipments of low-level radioactive wastes to these burial facil;. ties.

Examples of violations of Agreement State, DOT and NRC rules follow:

Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.

On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactiv4. material.

The material was described on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility.

The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.

On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material.

The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.

Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5, 1979, by the Agreement State of South Carolina, at the Barnwell, South Carolina bu al facility.

The shipments were from reactor, medical, industrial and military facilities.

On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for truck contamina-tion resulting from improper closures on 55-gallon drums of LSA material and for improper loading of the drums on the vehicle.

These are a few examples of shipm- =

' n ii ;<...',r,r:ccl;.17 - J"-f '

facilities which did not fully me which were developed to protect t DUPLICATE DOCUMENT Governors of the three States wit that if the situation is not rect Entire document previously would deny use of the three buria entered into system under:

~79 C SCO OE lf ano g

N o.

of pages:

OF* 7q og o7e g gg

-.- - m

-