ML19282C933
| ML19282C933 | |
| Person / Time | |
|---|---|
| Site: | 07106771 |
| Issue date: | 04/24/1979 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19282C929 | List: |
| References | |
| NUDOCS 7905070295 | |
| Download: ML19282C933 (2) | |
Text
, Fprna N A C -618 U.S. NUCLE AR REGUL ATORY COMMISSION U
}
iO CFR 71 CEnTIFICATE OF COMPLIANCE For Radioactive Materials Packages 1.(a ) Certificate Number 1.lb) Revision No.
1.(c) Packaae identification No.
1.(d ) Pages No. 1.te) Total No. Pages 6771 2
USA /6771/B( )
1 2
2.
PREAMBLE 2.(a)
This certificate is issued to satisf y Sections 173 393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Rejulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CF R 146-149), as amenced.
2.(b)
The packagmg and contents described in item 5 below, rneets the safety sttndards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions /
2.(t)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificafe is issued on the basis of a safety analysis report of the package design or application-3.(a )
Prepared by (Name and address) 3.(b)
Title and identification of report or application:
Teledyne Energy Systems flus Corporation application 110 West Timonium Road April 17, 1975, as supplemented.
Timonium, MD 21093 3.(c)
Docket No. J].677]
4 CONDITIONS This certdecate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item b below.
5.
Description of Packaging aruf Authorized Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a)
Packaging (1) Model No.:
Sft-1 (2) Description A shipping container for radioactive waste.
The packaging consists of an outer container which is a 4-inch thick right circular cylindrical steel shell. The cylinder is 80 inches in diameter and 84 inches high with a welded bottom plate and a cover secured by twenty-four,1-1/4-inch diameter steel bolts.
Impact limiters con-sisting of shock absorbing foam clad in 24-gage stainless steel are provided at the top and bottom of the container. The remainder of the cask is surrounded by a one-inch layer of canned insulation.
The maximum weight, including contents, is 60,000 pounds.
(3) Drawings The packaging is constructed in accordance with SUNTAC Nuclear Corporation Drawing No. B-08001, Revision E.
M b O ? o e_ W
Page 2 - Certificate flo. 6771 - Revision flo. 2 - Docket flo. 71-6771 5.
(b) Contents (1) Type and form of material Greater than Type A quantities of nonfissile radioactive material as solidified or dewatered waste.
(2) Maximum quantity of material per package.
Maximum decay heat load not to exceed 100 watts.
6.
The contents will be packaged in fourteen 55-gallon, DOT Spec. 17H drums; a single 170 cu. f t. DOT Spec. 60 inner container; or inner container (s) designed to meet burial site requirements.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
8.
Expiration date:
May 31, 1980.
REFERENCES NUS Corporation application dated April 17, 1975.
Supplement dated:
April 21,1975.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Stu Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety 4
Date: