ML19282C843

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 6144,Revision 3,for Radioactive Matl Shipping Package Model 6144
ML19282C843
Person / Time
Site: 07106144
Issue date: 04/23/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19282C842 List:
References
NUDOCS 7905070081
Download: ML19282C843 (3)


Text

,

Form NRC418 U.S. NUCLEAR REGULATORY CCMMISSloN

('

. 10 C h 71 CERTIFICATE OF COMPLI ANCE For Radioactive Materials Packages 1.(a) C 1.(b) Revision No.

1.(c) Package identification No.

1.(d ) Pages No. 1.(e) Total No. Pag

  • iN. e Number 3

USA /6144/B(

)

1 3

2. PREAMBLE

~

2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardo Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country thrcugh or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

l Teledyne Energy Systems Protective Packaging, Inc. Application 110 West Timonium Road dated March 4, 1974, as supplemented Timonium, MD 21093 3.(c) occkat No. 7 ]-6144

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specifi in item 5 below.
5. Description of Packaging and Authorized Contents, Model Number, Fissde Class, Other Conditions, and

References:

(a) Packaging (1) Model flo..

6144 (2) Description The packaging consists of a rectangular, double-walled box of welded mild steel construction with dimens-ions of 142 inches by 91 inches by 54 inches high' which encloses secondary containers.

The maximum weight of the loaded package is 42,000 pounds.

The double-walled box consists of an outer 1-inch thick steel shell and an inner 2-inch thick steel shelli separated by 56 shock tubes, eight on each end, and ten on each of the two sides, top and bottom.

The shock tubes are constructed of both 6-inch Schedule 40 and 8-inch Schedule 30 pipe.

The tubes are 5 inches in length and are welded to the exterior of the inner box.

The cover of the outer box is secured by forty-six, 1-1/4 inch diameter high strength bolts.

The lid of the inner box is sealed by two lengths of Garlock single lip closure seals and the seal pressure is maintained by steel springs which force the seal lip against the walls of the inner box.

N 05010

,y 9

Page 2 - Certificate No. 6144 - Revision No. 3 - Docket No. 71-6144 5.

(a) Packaging (continued)

(3) Drawings The packaging is constructed in accordance with Kenasco Corporation Drawing No. 6901-002B and Bill

~

of Material No. 6901 -002C.

(b) Contents (1) Type and form of material Radioactive material as solids or liquids, in normal or special forms packaged within DOT 17H, 55-gallon steel drums, or other secondary containers which meet the require-ments of Type A packaging.

(2) Maximum quantity of material per package Not more than Type B quantity radioactive material in each secondary container.

6.

The weight of the contents shall not exceed 5,000 pounds.

7.

Dunnage shall be provided in the shipping cask cavity sufficient to prevent movement of the secondary containers relative to the outer packaging under normal or accident conditions.

8.

Liquid contents must be additionally contained within an inner containment vessel which is surrounded by sufficient absorbent material to absorb at least twice th,e volume of the liquid contents.

9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.12(b).

10.

Expiration date:

December 31, 1979.

.. - = _

Page 3 - Certificate No. 6144 - Revision No. 3 - Docket No. 71-6144 REFERENCES Protective Packaging, Inc. application dated March 4,1974.

~

Supplement dated: August 12, 1974.

Chem-Nuclear Systems, Inc., supplement dated:

November 1, 1977.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Yf6u Yl Charles E. liacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety Date:

PR 2 31979 1l

- - - _ _.