O Form NRC418 U.S. NUCLEAR REGULATORY COMMISSICN
(
CERTIFICATE OF COMPUANCE 10 CFR 71 For Radioactive Materials Pacxages 1.(a) Cartificate Number 1.(b) Revision No 1.tc) P3cxage lcentification No.
1.(d) Pages No. 1.(et Total No. P3ge 9098 1
USA /9098/Bf )
1 3
- 2. PREAMBLE 2.fa)
This certificate is ruuad to satisfy Sections 173.393a 173.394 173.335. and 173.396 of tne Cecartment of Transcortation Hazarco Materials Regulations 149 CFR 170-189 and 14 CFR 103) and Sections 146-19-1Ca and 146--19-100 of tne Cepartment of Transportation Cangerous Cargoes Regulations (46 CFR 146-143), as amendeo.
2.!b)
The packaging and contents descibed in item 5 eelow, meets the safety standards set forth in Suecart C of Thfe 10, Code of Federal Regulations Part 71, " Packaging of Racioactive Materials for Transcort and Transportation of Rar=icactive Vatenal Under Cartain Conoitions.'*
2.(c)
This certificate does not relieve it's consignor from compliance with any recuirement of the regulations of the U.S. Ceoartment of Transportation or other applicaole regulatory agencies including the government of any country through or into wnicn the package will be transported.
- 3. This certi.'icate is issued on the basis of a safety analysis report of the package design or applicatiorW 3.(a)
Prepared by (Name and address):
3.fb)
Title and identification of report or application:
Union Carbide Corporation Union Carbide Corporation application dated P.O. Box 324 August 19, 1977, as supplemented.
Tuxedo, New York 10987 3.fe)
Occket No. 71-9098
- 4. CCNDITICNS This cartificate is conditionel uoan the fulfilling of the raauirements of Subpart o of 10 CFR 71, as apodicacle, and the conditions specified in item 5 below.
- 5. Cascription of Pacmaging and Authorized Contents Model Numcer, Fissde Class, Cther Conditions, arid
References:
(a) Packaging (1) Model No.: UCC-20WC-2 (2) Description A steel encased, wooden outer protective jacket with a uranium shielded cask and inner steel containment vessel. The protec-tive jacket is built to DOT Specification 20WC-2 with overall dimensions of about 25-1/4 inches by 28-3/4 inches high.
The shielded cask has a two-inch thick depleted uranium shield encapsulated in steel with a gasketed and bolted flange closure with an internal cavity 3.1-inch ID by 5-inch height. The inner containment vessel is a 2-1/2-inch Sch. 40 SS, gasketed and threaded pipe. The gross weight of the package is about 400 pounds.
(3) Drawings The packaging is constructed in accordance with Union Carbide Corporation Drawings Nos.:
101259, Rev. 0 100964C, Rev. C 79032206o(
Page 2 - Compliance No. 9098 - Revision No.1 - Docket No. 71-9098 5.
(Continued)
(b) Contents (1) Type and form of material Mo-99/Tc-99 in nomal form as solids or liquids.
(2) Maximum quantity of material per package 1000 curies 6.
Contents shall be contained within inner container described by Union Carbide Drawing No. 100712A, Rev. A.
The inner container shall show no leakage when tested to a sensitivity of at least 1x10 6 3
atm-cm /sec (1 atm of helium at 25 C leaking to a 1x10 2 atm ambient).
In addition, the neoprene gasket shall be replaced, and the inner container shall be leak tested, as described above, within 12 months prior to use.
7.
The loaded inner container shall show no leakage when tested to a sensitivity of at least 1x10 5 atm-cm3/sec (1 atm of air at 25 C leaking to a lx10 2 atm ambient) prior to each shipment.
8.
Structural parts of the packaging which could be used as tie-down devices shall be securely covered or locked during transport in such a manner as to prevent its use for that purpose.
9.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
- 10. Expiration Date: September 30, 1982.
Page 3 - Compliance No. 9098 - Revision No. 1 - Docket No. 71-9098 REFERENCES Union Carbide Ccrporation application dated August 19, 1977.
Supplement dated: January 16, 1979.
l FOR THE U.S. NUCLEAR REGULATORY COMMISSION
/w es cDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety I
Date: