ML19282B967

From kanterella
Jump to navigation Jump to search
Forwards LER 79-026/01T-0
Date released: 10/23/2019 Download: ML19282B967


LER 79-026/01T-0 on 790228:test Revealed 9.84% Failure Rate in 183 safety-related Self Drilling Anchor Bolts.Caused by Improper Installation.All safety-related Sys Hangers of That Type to Be Tested & Repaired
ML19282B969
Person / Time
Site: Hatch 
Issue date: 03/08/1979
From: Thomas Greene
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19282B969 (3)
Forwards LER 79-026/01T-0
ML19282B966
Person / Time
Site: Hatch 
Issue date: 03/08/1979
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19282B966 (1)