Form NRC418 U.S. NUCLE AR REGULATORY COMMIS$1oN CERTIFICATE OF COMPLIANCE 10 FR 71 For Radioactive Materials Packages Packan)e Identific.trian No.

$ ages No.1.(e) $tal No. Page 1.(d )

1.f a ) Certificate Number 1.ib) Revision No.

1.(c)

USA 6679/B( )F 6679 2

2. PREAMBLE 2.tal This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.096 of the Departroent of Transportation Hazardot Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Departrrent of Transpcrtation Cange<ous Cargoes Regulations (46 CFR 146-149), as arnended.

2.(b )

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Titte 10. Code of Federal Regulations, Part 71," Packaging of Radioactive Yaterials for Transport and Transportation of Radicactive Vaterial Under Certain Canaitions."

2.(c)

This certificate does not relieve the consignor from compliance with any recuirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the packags will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and addzess):

3.(b )

Title and identification of repcrt er application:

Teledyne Energy Systems Protective Packaging, Inc. application dated 110 West Timonium Road September 26, 1974.

Timonium, MD 21093 3.(c)

Docket No.

71-6679 4 CCNDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents, Model Number, Fissile C! ass, other Canditions, and

References:

(a) Packaging (1) Model No.:

Half Super Tiger (2) Description A protective overpack which provides containment, impact resistance and thermal resistance for its contents. The ccntainment vessel (cavity) is approximately 76" x 76" x 85" constructed of 3/16" thick and 10-gage mild steel.

Closure of the containment vessel is by 1/4" thick aluminum plate with silicone rubber gasket which is bolted to the containment vessel.

A pressure fitting with cap on the closure plate provides a means for leak testing.

The con-tainment vessel is centered and supported in an outer 3/16" thick steel jacket by approximately 17" of polyurethane foam insulation at the end and 10" on the sides. A removable section or cap consisting of approximately 18" of polyurethane

. foam insulation encased in steel with a silicone rubber gasket is bolted to the main outer steel jacket.

The overall dimensions of the packages are approximately 96" x 96" x 120".

Vent holes are provided on the sides and ends of the container.

Set into each corner of the outer container are standard I.S.0.

steel castings.

The maximum total weight including weight of the contents is 45,000 pounds.

79052503/(,

Page 2 - Certificate No. 6679 - Revision flo. 2 - Docket fio. 71-6679 5.

(a) Packaging (continued)

(3) Drawings Packaging is constructued in accordance with Protective Packaging, Inc., Drawings Nos. 32106-3, Sheet 1, Revision F and 32106, Sheet 2.

Argonne Transportation Shield is constructed in accordance with Drawings Nos. 32269, 32268, Revision A and 322170, Revision A.

ANL Waste storage bin is constructed in accordance with Drawing No. CS 2273.

(b) Contents (1) Type and form of material (i) Radioactive material including fissile material as solids or liquids, in normal or special form packaged in sccondary packaging which meets DOT Specification 7A, Type A general packaging.

(ii) Radioactive material including fissile material as solids, in normal or special form packaged in secondary packaging which meets DOT Specification 17C or 17H 55-gallon steel drums.

Fissile material concentration shall be no more than 5 grams fissile material in any liter.

(iii) Radioactive material including fissile material as solids, in normal or special form packaged in secondary pacakaging which meets DOT Specification 7A, Type A general packaging.

(iv) Radioactive material including fissile material as dry solids in normal or special form packaged in ANL waste storage bins contained within the Argonne Transportation Shield.

(2) Maximum quantity of material per package (i)

For the contents described in 5(b)(1)(i):

Greater than Type A quantity of radioactive material in secondary packaging.

Fissile material contents not to exceed the generally licensed mass limits as specified in 10 CFR 571.11.

Page 3 - Certificate fio. 6679 - Revision fio. 2 - Docket flo. 71-6679 5.

(b) Contents (continued)

(2) Maximum quantity of material per package (continued)

(ii) For the contents described in 5(b)(1)(ii):

Greater than Type A quantity radioactive materials in secondary packaging.

Eighteen 17C or 17H 55-gallon steei drums.

Each drum is limited to a maximum of 200 grams fissile material with no more than 5 grams fissile material in any liter and a maximum of 200 pounds of graphite.

(iii) For the contents described in 5(b)(1)(iii):

Greater than Type A quanity radioactive material in secondary packaging. flot more than 5 grams /ft3 fissile material.

(iv) For the contents described in 5(b)(1)(iv):

Greater than Type A quantity radioactive materials.

Fissile material contents not to exceed the generally licensed mass limits as specified in 10 CFR 571.11.

(c)

Fissile Class I, II and III (1) Fissile Class I For the contents c'escribed in 5(b)(1)(ii) and 5(b)(1)(iii) and limited in 5(b)(2)(ii) and 5(b)(2)(iii).

(2) Minimum transport For the contents described in index to be shown on 5(b)(1)(i) and 5(b)(1)(iv) label for Class II and limited in 5(b)(2)(i) and 5(b)(2)(iv):

As prescribed by 10 CFR 571.ll(b).

(3) Maximum number of For the contents described in packages per shipment 5(b)(1)(i) and 5(b)(1)(iv) and for Class III limited in 5(b)(2)(i) and 5(b)(2)(iv):

One (1)

9 Page 4 - Certificate flo. 6679 - Revision No.

Docket No. 71-6679 6.

The maximum gross weight of the package including contents, secondary packaging, dunnage, shoring and bracing must not exceed 45,000 pounds.

7.

The maximum decay heat generation per package must not exceed:

(i) 15 watts and the heat sources are distributed throughout the cavity such that the temperature at any point within the cavity does not exceed 200 F, or (ii) 104 watts provided combustible solids or liquids are not present and the heat sources are distributed throughout the cavity such that the internal surface temperature of the cavity walls will nowhere exceed 350 F.

(iii) 157 watts provided the ANL waste storage bins and transportation shield are used, combustible solids or liquids are not present and the heat sources are distributed throughout the cavity such that the internal surface temperature of the cavity wall will nowhere exceed 350 F.

The contents described in 5(b)(1)(ii) and limited in 5(b)(2)(ii) may be 8.

intermixed with the contents described in 5(b)(1)(iii) and limited in 5(t,)(2)(ii i).

9.

For less than full loads, sufficient dunnage, shoring and/or bracing shall be utilized to minimize secondary impact of the Type A packaging within the cavity under normal and accident conditions.

10.

Protrusions from Type A packaging such a; lifting eyes, etc., shall be positioned such that they will not ccnta;t the cavity walls, or shoring shall be provided to prevent puncture of the cavity walls by the protrusions under the normal and accident conditions.

11.

Radiation shielding as required shall be an intergral cart of the Type A packaging.

12.

Contents shall be positioned in the cavity such that the center of gravity of the loaded package is substantially the same as the center of gravity of an empty package.

13.

A leak test shall be conducted of each Half Super Tiger package prior to delivery to a carrier for transport to ensure that it is properly sealed. Where the Argonne Transportation Shield is used, the leak test may be conducted on the Argonne Transportation Shield in lieu of the Half Super Tiger package.

Page 5 - Certificate flo. 6679 - Revision flo. 2 - Docket fio. 71-6679 14.

Shipment of liquids where freezing may be encountered must receive approval with regard to arrangment made to prevent freezing of the contents.

15. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

16.

Expiration date:

February 29, 1980.

REFEREtiCE Protective Packaging, Inc. application dated September 26, 1974.

FOR THE U.S. IlUCLEAR REGULATORY COMMISSI0il Yb h0't Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and Material Safety APR ' " 197]

Date:

~