,.e APR 0 61379 FCTR:WHL 71-9352 U.S. Department of Energy ATTit:
Dr. William E. Mott Washington, DC 20545 Gentlemen:
This refers to your letter dated August 2,1978, requesting our review of the Model No. DT-14 shipping package.
In connection with our review of this package, we need the information identified in the enclosure to this letter.
Please advise us when this information will be provided.
Sincerely, h
ui.
m-Charles E. MacDonald, Chief Transportation Branch Division of Fuel Cycle and itaterial Safety
Enclosure:
As stated cc:
DOE, Oak Ridge Operations Office ATTil: tir. William H. Travis P.O. Box E Oak Ridge, Til 37830 790502o17o
Model fio. DT-14 Docket flo. 71-9852 A
Enclosure to ltr dtd:
STRUCTURAL Demonstrate that the integrity of flanged and bolted containment vessel, shown in Figure 3 of Report flo. Y/DD-244, January 1978, maintains its integrity for a 30-foot bottom end drop with maximum content weight.
C0:lTAIllMErlT 1.
Develop a contain=nt criteria based on the dispersibility and radiotoxicity of the contents for normal conditions of transport and accident damage conditions.
Regulatory Guide 7.4 may be used in establishing this criteria.
2.
Demonstrate that the containment vessels (shown in Figures 3 and 4 of Report flo. Y/DD-244, January 1978) meet the established containment requirements for normal conditions of transport and accident damage conditions.
TESTIilG AtlD MAIllTEtlAtlCE Establish a test and maintenance plan for the containment vessels in 3ervice.
Regulatory Guide 7.4 may be used for periodic testing.
For atsembly verification it is recommended that a test of sufficient sensitivity to limit the maximum relase to a type A quantity in 10 days 3
is used, however, a leak test sensitivity greater than lx10~3 at-cm /sec, 3
would not be required. The minimum sensitivity of lx101 at-cm /sec (air at 1 atm and 25 C leaking to a 10 2 at ambient) as specified in AflSI fil4.5 should be met.