ML19281A653

From kanterella
Jump to navigation Jump to search
Informs of Completion of Review of Amend 17 to Psar. Determines Section 13.2 Should Be Revised
ML19281A653
Person / Time
Site: 05000502
Issue date: 03/05/1979
From: Collins P
Office of Nuclear Reactor Regulation
To: Parr O
Office of Nuclear Reactor Regulation
References
NUDOCS 7903260406
Download: ML19281A653 (2)


Text

'

i o

\\

P['an asc '*g

/- w {s UNITED STATES 3'k.

NUCLEAR REGULATORY COMMISSION 4

5!(Mlij WASHINGTON, D. C. 20555 5,kkl #l

+.$.*

MAR 5 G79 Docket No. STN-50-502 MEMORAN00M FOR:

0. D. Parr, LWR Branch #3, DPM FROM:

P. F. Collins, Chief, Operator Licensing Branch, DPM

SUBJECT:

HAVEN NUCLEAR PLANT APPLICANT:

Wisconsin Utilities Project DOCKET N0:

STN-50-502 LICENSING STAGE: CP BRANCH AND LPM REQUESTING ASSISTANCE:

LWR-3, R. A. Capra REVIEW BRANCH INVOLVED: OLB:DPM REVIEW STATUS:

Second Round Questions We have reviewed the additional infonnation sutxnitted for Section 13.2 of the PSAR as Amendment 17. Based on our review, we have determined that Section 13.2 should be revised, as indicated in Attachment A, to bring the PSAR into confonnance with previously approved submittals. We will be available to discuss these items, should the applicant desire.

'fgir.:L /?/S-f*

/,falfl F. Collin, Chief d 0derator Licensing Branch Division of Project Management cc:

D. Skovholt W. Haass D. Vassallo R. Capra W. Pike

Enclosure:

Attachment A 79032664o6

ATTACHMENT A WISCONSIN UTILITIES PROJECT HAVEN NUCLEAR PLANT DOCKET NO. STN 50-502 440.0 OPERATOR LICENSING BRANCH 441.1 The comnitment to conduct an initial fire orotection (13.2) training program does not mea

  • the recuirements of Standard Review Plan Section 13.2.

Tc meet these requirements, please provide the folicwing:

1.

A camnitment to complete the initial fire protection training prior to receiot of fuel at the site.

2.

The provisions that have been made for the indoctrination of constructicn personnel.

3.

A detailed description of the training program for the individual (s) responsible for the form-ulation and assurance of the implementation of the fire protection program. A commitment to meet the requirements of Section A.1 of Aapendix A to Branch Technical Position ASB 9.5-1, Guidelines for Fire Protection for '!uclear Prie-31an s, may be made in lieu Of s;b-i--i g i :r:g'a ces:ric-tien.