1 NRR-DRMAPEm Resource From:
Lee, Samson Sent:
Friday, October 4, 2019 10:25 AM To:
Williams, Christian D:(Exelon Nuclear)
Subject:
FitzPatrick Emergency amendment public conference call discussion points - 6 The licensee should check the last paragraph of page 4 of 15 of the draft attachment. In that paragraph, it stated that, for a DBA LOCA with only offsite power available through the remaining transformer, 71T-2, Reserve Station Service Transformer T2, the LOCA analysis is dependent on the full complement of equipment served by the 10600 bus. It may imply that the AC power via 71T-2 is required. However, the DBA LOCA was performed with the assumption of Lost of Offsite Power (see, for example, Fitzpatrick UFSAR Sec.
6.5). This statement should be consistent with the UFSAR.
- Thanks, Sam
Hearing Identifier:
NRR_DRMA Email Number:
245 Mail Envelope Properties (BL0PR0901MB3185D1C5A77464013EE233E79A9E0)
Subject:
FitzPatrick Emergency amendment public conference call discussion points - 6 Sent Date:
10/4/2019 10:25:06 AM Received Date:
10/4/2019 10:25:00 AM From:
Lee, Samson Created By:
Samson.Lee@nrc.gov Recipients:
"Williams, Christian D:(Exelon Nuclear)" <Christian.Williams@exeloncorp.com>
Tracking Status: None Post Office:
BL0PR0901MB3185.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 601 10/4/2019 10:25:00 AM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: