ML19276H345

From kanterella
Jump to navigation Jump to search
Notifies That Revisions Are Necessary to FSAR Section Re Operator Requalification.Items for Change Encl
ML19276H345
Person / Time
Site: Crane 
Issue date: 03/19/1974
From: Collins P
US ATOMIC ENERGY COMMISSION (AEC)
To: Bernero R
US ATOMIC ENERGY COMMISSION (AEC)
References
NUDOCS 7910160685
Download: ML19276H345 (3)


Text

-

MAR 19 1974 Occi. it tio. 50-239 R.

't. Eernero, Project ?!anager, Licht Water Reactors 3 ranch 2-3, L TIIREE : FILE ISLA'ID OPERATOR RCUALIFICATIO'? PROCRA" We have received and reviewed A=end=ent 47 to the FSA* for the Three Mile Island :Tuclear Generating Station, dated March 3,1974, in which the operator recualification program is described.

Based on our review, we have concluded that souc revisions are necessarv for the program to meet the requirements of Sections 50.34(h)(8) and 50.54(1-1) of 10 CFR Part 50 and Appendix A of 10 CFR Part 55.

The revisions are indicated below and are referenced to the appropriate sections of the Three Mile Island submittal.

II A.

Item - We believe that the grade criterion should be 80% for determining that an individual requires additional training in a particular area or subject.

II B.

Iten - We believe it is inappropriate to commit the Operator Licensing Branch to supplying specifics of our examination results to facility management. Therefore, the last sentence of the 1st parngraph should be deleted.

Item - The FSR program is described as consisting of self-study assignments, possible tutorial sessions with designated technical instructors and evaluation quizzes. Appendix A of 10 CFR Part 55 specifically requires the indicated subjects to be part of a preplanned lecture series.

In order to comply with the requirements of Appendix A, a statement should be included that no more than 50*

of the FSR progran may be accomolished through the reans of films, videotapes and/or individual study.

Item - We believe that the grade criterion for the FSR evaluation quiz should be 80% instead of 70%.

'420 026 7 910160 h5

2-

< 5. & G7i

~ Three '4tle Island II!.

Item - The list of reactivitv naninulations nust to more definitive.

Ite-1 nust be nore accuratelr Jeccribel. Itaa 2 is acceptabic only if it includes a startua to the point of addina, hn2t and states this.

Itcu 4 =ust be accomplished with the reactor contrcl systeu in manual.

Item 5 in not considered an acceptabic reactivity uanipulation.

Item - It should be specifically stated that the additional operationa lirted are not censidered to be reactivity manipulat'_ons for cradit.

Item - The program, as described, is designed to be administered on site.

However, the program states that a sioulator may be used in meeting the on-the-job trainina section of the pror, ram.

'ie would consider the use of a si=ulator to be a significant change pursuant to Section 10 CTR Part 50.54(1-1),

consequently, we would have to review the plan prior to Laplementation.

IV.

Item - The second item of the standards applving to the annual writte evaluation examinations should be revised to show 80% as the minimum category grade on the annual written examination.

Item - We believe that an additional criterion should be added to the four otandards listed on page 123-8, so that if an individual receives a grade of less than 70% overall on the annual examination it should be mandatory that he be placed in an accelerated requalification nrogram. His participation in the accelerated program should ha such that it would preclude perforning licensed duties.

The duration and course content, of course, =ust be determined in each case.

VI.

Item - A cartification of a satisfactorv rating must be made to the AEC prior to the individual's return to licensed duties.

1420 027

~

MAR 101974

'"hree "ile Island VIII.

Ite:c - 5.'a do not believe it i-aaprontiate for the Onerator Licensing " ranch to 'ce connitted to sunplv anv infor:r.tian to the 'neility reqardir-an individual other than a license or denial letter. Vo believe that there are sufficient facility evaluations availabic !=nediatelv nrior to the adeinistration of our exauf nation: to determine the need for additional tratr.in,.

Therefore, the 2nd sentence of the lot paravraph shou 11 be deleted.

ORfCINAL

r.,. copo ev Paul F. Co lins, Chief Operator Licensing Branch Directorate of Licensing ec:

A. Schwencer DISTRIBUTION:

OLB R/F JJHolman Central Files 1420 028

' ) )'

omcr >

OLB:L.

.O..L..E...:.L 4

_ a.

JJ1kO.i5iiEidif PFCol ns sumur >

. s.4.

31/Yl74 om >

31/..tf/74 Toe.n AIC-313 i Rev. 9-53) AICM 0240 u.s.

sanee i eeaareae oaaeu !U t.u3-506

-