U.S. NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT Region I Report No. 70-33/79-01 Docket No. 70-33 Safeguards Group 1
License No. SNM-23 Priority I
Category Ur Licensee:
Texas Instruments, Incorporated 34 Forest Street Attleboro, Massachusetts 02703 Facility Name:
Texas Instruments, Incorporated Inspection at:
Attleboro, Massachusetts Inspection conducted:
nuary 16-1, 1979 Inspectors: f fAdf 2.
- 2. 79 P.'. diYsett' Saf guards Auditor date signed
/ hA \\[
2 < 2 79 E. T. Shaub, Safeguards Technician date signed
- k. k.
W_,~ \\
DT J9 R. J.J Summers, Safeguards Auditor date signed Approved by:
/Y JAv 2 7 9'
(). H. Joy"ner, Chief, Nuclear Material date signed Control Support Section, Safeguards Branch Inspection Summary:
Inspection on January 16-19, 1979 (Report No. 70-33/79-01)
Area Inspected:
Routine unannounced inspection by regional based inspectors of nuclear material contral and accounting in the area of: measurement and statis-tical control.
The inspection involved 72 inspector-hours on site by 3 NRC regional based inspectors.
Resul ts:
In the area inspected, no items of noncompliance were identified.
Region I Form 12 (Rev. April 77) 7903220 6
DETAILS 1.
Persons Contacted
- F. Sherman, Manager, HFIR Projcet
- C. Hopper, Manager, Nuclear Materials & Safety
- D.
Talan, Nuclear Material Officer
- S. Roman, Manager, Quality Assurance
- denotes those present at the exit interivew.
2.
Organization An organizational change has been instituted by the licensee.
The revisad organization structure has the Manager, HFIR Project, reporting to the MSD Manufacturing Manager.
This change has not decreased the overall effectiveness and control of the Nuclear Material Control and Accountability Section.
No items of noncompliance were noted.
3.
Measurement and Statistical Control Non destructive assay was performed by the inspectors on HFIR fuel plates using the Tracor Northern-1705 Multi Channel Analyzer with a 2 "x 2" sodium iodide [NAI(TL)] crystal.
The " standard plate" technique was used to measure the fuel plates.
The licensee's gamma standard plate was measured twenty times for calibration and determination of error for the assay system.
Measurements were made on 572 plates, representing twenty-four lots, randomly selected from the total of forty-seven lots on inventory.
The results of the measurements are depicted in the following table.
3 ATTRIBUTES CERTIFICATION 1.
Number of Items
- in the Category 1128 2.
Number of Sampled Items Selected by NRC 572 3.
NRC Reproductibility Limit for an Individual Item in the Category 10%
4.
Number of Sampled Items for Which Licensee's Value exceeds NRC Reproductibility Limit 0_
5.
Maximum Number of Category Items at the 95%
Confidence Level where Licensee's Value exceeds NRC Reproductibility Limit (The
" maximum number" is statistically inferred utilizing the hypergeometric probability distribution) 4 VARIABLES CERTIFICATION 1.
Licensee Determination of Total Grams in the Category. (LIC) 20,085 2.
NRC Estimate of Total Grams in the Category based on the measured results of the 24 Sampled Lots.
(NRC) 20,058 3.
Difference Between the Licensee Determination and the NRC Estimate of Total Grams in the Category.(LIC-NRC) 27 4.
Limit of Error Associated with the Difference Between the Licensee Determination and the NRC Estimate of Total Grams at the 95%
Confidence Level [LE(LIC-NRC)]
600 5.
Is the Difference Statistically Significant, i.e., Does (LIC-NRC) en eed [LE (LIC-NRC)]?
No
- Item = HFIR fuel plate
4 4.
Exit Interview The inspectors met with the licensee representatives (denoted in Paragraph 1) at the conclusion of the inspection on January 19, 1979. The inspectors sumarized the purpose and scope of..:le inspection and the findings.