Board Notification 84-076:provides Info Re Westinghouse Reactor Coolant Pump Seal Potential for Failure Under Loss of Cooling Conditions.Info Updates Board Notification 83-139 & Aecl Test Results
ML19276B030
Person / Time
Site: Indian Point, Catawba, Wolf Creek, Byron, Seabrook, Diablo Canyon, Callaway, Comanche Peak, 05000000
Issue date: 04/19/1984
From: Eisenhut D
Office of Nuclear Reactor Regulation
To: Gilinsky, Palladino, Roberts
NRC COMMISSION (OCM)
Shared Package
ML19276B031 List:
References
TASK-AS, TASK-BN84-076, TASK-BN84-76 BN-84-076, BN-84-76, NUDOCS 8404160150
Download: ML19276B030 (2)


Text

.

Central Files Only Docket No.: 50-275/323 April 19,1984 50-483 50-247/286 MEMORANDUM FOR:

Chairman Palladino Connissioner Gilinsky Connissioner Roberts Coanissioner Asselstine Connissioner Bernthal FROM:

Darrell G. Eisenhut, Director Division of Licensing

SUBJECT:

BOARD NOTIFICATION REGARDING WESTINGHOUSE REACTOR COOLANT PUMP SEALS (BN-84-076)

In accordince with the procedures for board notification, the following information is being transmitted directly to the Commission. The appropriate boards are being notified by copy of this memorandum. This information is applicable to Diablo Canyon, Callaway and Indian Point 2/3 which are currently before the Conmission.

This recent information updates the information provided in BN-83-139 and Atomic Energy Canada Limited test results that may indicate a potential for Reactor Coolant Pump Seal failure under loss of cooling conditions. As stated in BN-83-139 this issue may ultimately raise a new safety concern and is therefore being forwarded for your information.

However, the staff recognizes that the conditions of the test represent events which are currently beyond the designed basis.

i trit rk.

3D i

r Darrell G. Eisenhut, Director Division of Licensing

Enclosure:

Memo Vollmer co Eisenhut 4/6/84 See Next Page for cc's

\\

RStark j DGE t

4/

/84 4/

/84 8404160150

. ASLB FOR:

Byron - 50/454/455 (Snich, Callihan, Cole)

Callaway 483/486 (Gleason, Bright, Kline)

Catawba 413/414 (Kelly, Purdom, Foster)

Comanche Peak-50-445/446 (Bloch, Jordan, McCollom)

Seabrook - 50/433/434 (Hoyt, Harbour, Luebke)

Wolf Creek 482 (Wolfe, Anderson, Paxton)

ASLAB FOR:

Callaway 483/486 (Rosenthal, Edles, Gotchy)

Byron 454/455 (Rosenthal, Gotchy, Kchl)

Diablo Canyon 275/323 (Moore, Buck, Johnson)

Catawba 413/414 (Rosenthal, Mo'are, Wilber)

OPE OGC SECY (2)

EDO s-

l* "t c v

,,n

,g UNITED STATES y, ).c,, (

NUCLEAR REGULATORY COMMISSION 5 f-

p WASHINGTON. D. C. 20s55 5

c

%, '...../

APR 0 6 1984 MEMORANDUM F0R:~DavveMMMME$6hNTfffE40C Division of Engineering FROM:

Richard H. Vollmer, Director Division of Engineering

SUBJECT:

BOARD NOTIFICATION REGARDING WESTINGHOUSE REACTOR COOLANT PUMP SEALS

Reference:

Memo from D. Eisenhut to the Commission, dated September 21, 1983, Board Notification Regarding Westinghouse Reactor Coolant Pump Seals (BN-83-139)

As part of the confirmatory research programs related to equipment quali-fication, RES is conducting scale model tests at Atomic Energy Canada, Limited (AECL) of secondary seals (0-rings and channel seals) which are an integral part of the seals of some reactor coolant pumps (RCP).

These tests simulate the conditions which RCP seals would be subjected to during station blackout.

Preliminary indications from AECL indicate failure to seal in some small size 0-ring tests for a range of test conditions which is both more and less severe than the conditions established by Westinghouse for its pumps.

The tests are continuing in order to verify the behavior and complete the planned test program.

These scaled 0-ring and channel seal tests are to be conducted over a -ange of pressures, temperatures, and gap sizes which will bracket the conditions established by Westinghouse for its pumps.

Westinghouse is in the process of submitting an analysis to the staff which establishes lower pressure differentials and somewhat lower temperature conditions for the 0-rings and channel seals.

This analysis is subject to staff review.

A contractor has also been selected to do an independent verification review of the Westinghouse calculations.

Although the tests arc still in progress at AECL and the results are to be considered preliminary at this time, we recommend board notification of this additional information as it relates to the previous referenced board notification.

tl

^

Richard H. Vollmer, Director Divis;on of Engineering

Contact:

J. Jackson, NRR Ext. 27930 cc:

See next page N[

ggt 70A

('DL Gff.

DISTRIBUTION H. Denton E. Case R. Vollmer D. Eisenhut R. Ma' an T. Spc C. Heltemes L. Rubenstein F. Rowsome G. Lainas T. Novak J. P. Knight F. Miraglia L. Wheeler V.

Noonan G. Bagchi J. Jackson O. Parr A. Thadani W. Minners B. Sheron B. D. Liaw A. Buslick J. Tsao s

R. Riggs E. Brown K. Seyfrit R. Kirkwood J. Wilson E. Sylvester J. Guttman C. Liang A. Marchese A. Rubin P. Baranowsky M. Caruso J. Holonich J. Richardson W. Campbell

DISTRIBUTION LIST FOR BOARD NOTIFICATION Byron Units 1&2, Docket hos. 50-454/455 Sen. Gordon J. Humphrey Callaway Unit 1, Docket No. 50-483 Mrs. Phillip B. Johnson C;tawba Units 1&2, Docket Nos. 50-413/414 Dr. W. Reed Johnson Comanche Peak Units 1&2, Docket Nos. 50-445/446 Dr. Walter H. Jordan Diablo Canyon Units 1&2, Docket Nos. 50-275/323 William S. Jordan, III, Esq.

Scabrook Units 1&2, Docket Nos. 50-413/444 James L. Kelley, Chairman Wolf Creek Unit 1, Docket No. 50-482 Janice E. Kerr, Esq.

Dr. Jerry Kline Dr. Robert M. Lazo Atomic Safety and Licensing John Clewett, Esq.

Ms. Karen E. Long Board Panel Dr. Richard F. Cole Mr. Harold Lottman Atomic Safety and Licensing Mr. John T. Collins Dr. Emmeth A. Luebke Appeal Panel Mr. Nicholas J. Costello Mr. Fred Luekty Brentwood Board of Selectmen Philip A. Crane, Jr., Esq.

Mr. Angie Maciiiros Division of Consumer Counsel Charles Croe>, Esq.

Morton B. Margulies, Esq.

Docketing and Service Section Edward L. Cross, Jr.

Mr. John Marrs Document Management Branch Mr. James E. Cummins Dr. Kenneth A. McCollom Palmetto Alliance Thomas G. Dignan, Jr., Esq.

J. Michael McGarry,III, Esq.

Region III, U.S.N.R.C.

John F. Doherty Patrick J. McKeon Town Manager's Office Jane Doughty Mr. Edward F. b %

Town of North Hamnton Mr. Owen B. Durgin Michael Miller, Esq.

Gary J. Edles, Esq.

Pror. William H. Miller Phillip Ahrens, Esq.

Eric A. Eisen, Esq.

Thomar S. Moore, Esq.

Dr. George C. Anderson Mr. FreJerick Eissler Ms. Pat Morrison Mrs. Elizabeth Apfelberg Mrs. Juanita Ellis Mr. H. Daniel Nix Maur he Axelrad, Esq.

David S. Fleischaker, Esq.

Bruce Norton, Esq.

Robr.t A. Backus, Esq.

Mrs. Raye Fleming Dr. Hugh C. Paxton Mr. Samuel J. Birk Dr. Richard F. Foster Spence Perry, Esq.

Mr. Richard E. Blankenburg R. K. Gad III, Esq.

C. Edward Peterson, Esq.

Peter B. Bloch, Esq.

Joseph Gallo, Esq.

Ms. Roberta C. Pevear Mr. Dan I. Bolef Billie Pirner Garde William L. Porter, Esq.

Mr. Donald Bollinger Ms. Sar.dra Gavutis Sen. Robert L. Preston Mr. Glenn 0. Bright Arthur C. Gehr, Esq.

Dr. Paul W. Purdom Mr. Earl Brown Ellen Ginsberg, Esq.

Ms. Diana P. Randall Mr. William L. Brown James P. Gleason, Esq.

Mr. John G. Reed Dr. John H. Buck Dr. Reginald L. Gotchy Ms. Marjorie Reilly Dr. A. Dixon Callihan Robert Guild, Esq.

Joel R. Reynolds, Esq.

Mr. Calvin A. Canney Mr. Lee M. Gustafson Nicholas S. Reynolds, Esq.

Doug Cassel, Esq.

Dr. Jerry Harbour Mr. Jesse L. Riley Brian P. Cassidy, Esq.

Mr. Thomas H. Hariis Alan S. Rosenthal, Esq.

A. Scott Cauger, Esq.

Mr. Robert J. Harrison Ms. Mary Ellen Salava Mr. Kenneth M. Chackes Donald L. Herzberger, MD Mr. Alfred Sargent Gerald Charnoff, Esq.

Renea Hicks, Esq.

Mr. James 0. Schuyler Ms. Diane Chavez Ms. Beverly Hollingworth Mr. Lewis Shollenberger Mr. Donald E. Chick Dr. Frank F. Hooper Ms. Jo Ann Shotwell Ms. Wanda Christy Helen Hoyt, Esq.

Ms. Barbara Shull Mr. Mendall U ark Mr. Richard B. Hubbard Jay E. Silberg, Esq.

4 DISTRIBUTION LIST FOR BOARD NOTIFICATION Byron Units IL2, Dusket Nos. 50-454/455 Callaway Unit 1, Docket No. 50-483 Catawba Units 1&2, Docket Nos. 50-413/414 Comanche Peak Units 1&2, Docket Nos. 50-445/446 Diablo Canyon Units 1&2, Docket Nos. 50-275/323 Seabrook Units 1&2, Docket Nos. 50-443/444 Wolf Creek Unit 1, Docket No. 50-482 Mr. Gordon Silver ACRS Members John M. Simpson, Esq.

Dr. Robert C. Axtmann Mr. Lanny Alan Sirkin Mr. Myer Bender Ivan W. Smith, Esq.

Dr. Max W. Carbon Carol S. Sneider, Esq.

Mr. Jesse C. Ebersole Mr. Michael D. Spence Mr. Harold Etherington Major Howard Steffen Dr. William Kerr Mr. Michael J. Strumwasser Dr. Harold W. Lewis Dr. Mauray Tye Dr. J. Carson Mark Paul C. Valeritine, Esq.

Mr. William M. Mathis Ms. Anne Verge Dr. Dade W. Moeller Dr. Bruce Von Zellen Dr. David Okrent Howard A. Wilber, Esq.

Dr. Milton S. Plesset Mr. Donald R. Willard Mr. Jeremiah J. Ray Mr. Harry M. Willis Dr. Paul C. Shewmon Richard P. Wilsan, Esq.

Dr. Chest 3r P. Siess John F. Woll, Esq.

Mr. Day.a A. Ward Sheldon J. Wolfe, Esq.

Mr. Robert A. Wooldridge Mr. Robert G. Wright Board Notification 84-076 Branch Service Lists of addressees receiving material on ' e following dockets:

BYRON DOCKET Mr. Dennis L. Farrar Mr. William Kortier Mr. Michael Miller, Esq.

Mr. Edward R. Crass Mr. Julian Hinds CALLAWAY DOCKET Mr. D. F. Schnell Mr. Nicholas A. Petrick Mr. J. E. Birk Resident aispector Mr. Donald W. Capone Regional Administrator, Region III CATAWBA DOCKET Mr. H. B. Tucker North Carolina MPA-1 Mr. F. J. Twogood Mr. J. C. Plunkett, Jr.

Mr. Dierce K. Skinner North Carolina Electric Membership Corp.

Saluda River Electric Cooperative, Inc.

Mr. Peter K. VanDoorn Regional Administrator, Region II Spence Perry, Esq.

Mark S. Calvert, Esq.

Page 2 Board Notification 84-076 Branch Service Lists of addressees receiving material on the following dockets:

COMANCHE PEAK DOCKET Robert A. Wooldridge, Esq.

Mr. Homer C. Schmidt Mr. H. R. Rock Mr. A. T. Pai:r-William Burchette, Esq.

DIABLO CANYON DOCKET Mr. Malcolm H. Furbusn Mr. Lee M. Gustafson Resident Inspector /Diablo Canyon NPS Dr. Jose Roesset Dr. William E. Cooper Mr. W. C. G~angloff Regional Administrator, Region V 3EABROOK DOCKET Bruce Beckley D. Pierre G. Cameron, Jr., Esq.

Regional Administrator, Region I E. Tupper Kinder, Esq.

Resident Inspector Mr. Juhn DeVincentis Mr. A. M. Ebner Mr. Stephen D. Floyd Ms. Letty Hett Honorable Richard E. sullivan Seacoast Anti-Pollution League WOLF CREEK DOCKET Mr. Glenn L. Koester Mr. Nicholas A. Petrick Mr. Donald T. McPhee Resident Inspector Teri Sculley Regional Administrator, Region IV Mr. Joe Mulholland Regional Administrator, Region III