2%

..__ Franklin Research Center A Dwision of The Franklin Institute April 30, 1980 United States Nuclear Regulatory Co==ission Washington, D.C. 20555 Attention:

Pr. E. J. Butcher, Jr.

Project Officer

Reference:

FRC Project CS257 NRC Contract NRC-03-79-118 NRC TAC No. 10912 FRC Task No. 24

Title:

Technical Evaluation Report, Sntain=ent Leakage Testing, Indian Point Unit 2

Dear Pr. Butcher:

Attached is the Technical Evaluation Report of the submittal of the Consolidated Edison Company of New York, Inc. relating to Contain=ent Leakage Testing for Indian Point Unit 2.

Bis co=pletes FRC's efforts on FRC Task No. 24.

Very truly yours, M

S. P. Carfa,no e

Project Manager SPC/TDC/dg cc:

E. C. Adensa:

Y. S. liuang Attach.

8007010 The Se. jam:n Frandn Paha3. Phi:ade'phia Pa 19103 (215)44S-1000 TWX-710 6701889