Summary of 791218 Meeting W/Pottstown Trap-Rock Quarries Inc,Perkins Run Blasting,Inc,Leet Associates,Cvw Industries, USGS & NRC Re Evaluation of Effects of Blasting at Sanatoga Quarry on Facility
ML19275C316
Person / Time
Site: Limerick  
Issue date: 02/27/1980
From: Kane J
Office of Nuclear Reactor Regulation
To: Rolonda Jackson
Office of Nuclear Reactor Regulation
References
NUDOCS 8003200214
Download: ML19275C316 (4)


Text

.

y.

.u a

IES 3 7 DJo i

t NESCRA!!DUi1 FOR:

Pobert E. Jackson, Chief Geosciences Branch, CSS THRU:

Lynan W. Heller, Leader Geotechnical Engineering Section Geosciences Branch, DSS FRO:4:

Joseph D. Knoe, Geotechnical Enqineer Geotechnical Encineerina S?ction Geosciences Branch, DSS

SUBJECT:

L'EETIt:G WITH POTTSTO',13 TRAP ?CC" QUARRIES, I::C.

PLA'!T '!A' E : Linerick loclear rennrating Station, nits 1 & 2 LICE: SI::G STA';E: Post Cp DOCKET t'UPBER: E0-352/353 A meeting at the Sanatoga Plant which is operated by Pottstown Trap-Rock Guarries, Inc. was held on the m rning of December 13, 1979. Representatives attending this meting are noted on the enclosed list. The meetino with quarry officials was requested by the staff of ?:RC to assist '.RC consultant, the U. S. Geological Survey, in evaluating the effects of blastinq at the Sanatoga quarry on the construction and future operation of the Limerick Generating Station. The approximately 65 feet to 80 feet high existing quarry face is about 3G00 feet from the reactor buildings of the Lincrick facility.

Discussions on Decenber 18, 1979 with quarry officials and their blasting and seismological consultants revealed the following information:

A.

Blast infornation 1.

A typical blast would have the following characteristics:

a.

Up to 13 holes; 6 inches in dia.eter; 12 feet snacing; 20 feet throu; 14 to 13 feet ste ninq b.

Explosives consist of CC0 pounds of stick slurry (Amonium iittrate with fuel oil) and several one pour riynamite boosters perhhole.

c.

Two electrical blasting caps with delays from 10 to 33 1.$llia;vcuda Iiv i,

a. ;

uscu ga orrics >

"Tlieref ]re, maifhun ch"arge ud 5 filii er"5f ay"fs "4 !Q" pounE evnwa ns h oavs >

NRC PORM 318 (9 76) NRCM 0240 W v.s.......,...= vine en n ee s i s e e s - e.. - e s e d

42 I !'

FEB <>,.~,

~4 l

2.

Primacord not used in order to reduce air blast and acoustic I

noise.

3.

Holes drilled 3 to 4 feet below quarry floor which causes break out to remain at ficor level.

4 Frequency of blastino - one every 4 to 5 weeks.

I 5.

f.'o explosive storane en site except for the day (s) of loading.

i B.

Other 1

l. Geology - The guarry site is situated in Brunswick Shale whose dip is 5 to 15 to the NW.

Consequently, the blast locations are stratigraphically higher than Limerick plant site. The specific horizons in which the blastinq occurs when projected toward the Lioerick plant would be nany feet above the present surface and consequently have been eroded away.

2. Each blast conducted by Pottstown Trap-Rock Quarries, Inc. is monitored by their seismological consultant. Monitoring records available at the meeting on past shots indicated peak particle velocities well within the limits of the State and Federal regulations.
3. Future quarry expansion would appear to allow the top edge of quarry face to advance to within 50 feet of the property line adjoining the Limerick j

plant area. This is an approximately 450 feet advance from the existing quarry location.

An opinion was expressed that it is likely a creater threatffrom a blast on the Linerick plant would come fren the nearby Pottstown Firestone plant, where large chemicals are thought to be required, than from operations at the Sanatoga quarry.

Aerial colored photograpos, 11" x 14" in size, were kindly provided by quarry officials for URC use. These photos give a clear view of the quarry's location in relation to the construction at the ainerick plant.

The above meeting minutes have been coordinated with D. Tibbitts and J. Devine, USGS.

i Joseph D. Kane, Geotechnical Engireer Geotechnical Engineering Section Geosciences Branch, DSS

Enclosure:

^r tzt2d o ric=g

. 3g...g.g....

..... = >.

mars >>

NEC PORM 318 (9-76) NRCM 0240 8 u.a **ve==asse mentine oreus a e ve - ao s. v..

7 FEB+,~(

f 'idd t

{

cc: w/ enclosure J. I',n i gh t P.. Jackson j

L. Heller L. Reiter l

D. Tibbitts l

J; Devine, USGS i

J. Kane i

F. Willians l

PDR i

I i

DISTRIBUT'"!!:

DOCKET F iE (50-352/353)

GSB RDG 4

L I

i i

r l

i t

I i

1 i

i

..fg.;GSR.

..DS.S.;.0.53%%...P.S.S.

. nc = >

- =*

..do.Kane:.sh.

..LWHe.l.1e c.../.....% 4 Aef...

.2/ix89.2$.00.zt)JY.,

~c*

2120/80..

' unc eonu m o.m uncu oua

  • ..... ~.- -,...............,..

L.

. _.... ?.

(:

Attendance List Meeting at Sanatoga Plant - Pottstown Trap-Rock Quarries, Inc.

December 18, 1979 Project: Limerick Nuclear Generating Station i

I Name Representing James Florig Pottstown Trap-Rock Quarries, Inc.

Ted Hinaman R. L. Graham D. J. Selamone Perkins Run Blasting, Inc.

A. DeLeo Jr.

Leet' Associates A. MacPhee C.V.W. Industries A. Varela tiRC, I&E Region I J. Mattia J.Dehine U.S.GeologicalSurYey D. Tibbitts I;RC, DPM J. Kane t;RC, DSS 4

i s

E

.t I

t L

%