TC d
^~'/
/
'e-
- g.. q
'o, UNITED STATES E'
NUCLEAR REGULATORY COMMISSION 5I n
<f E
REGION ill 8
709 ROOSEVELT ROAD o, pg,.....,/
cLEN ELLYN. ILLINOIS 60137 AUG 101973 Docket No.70-925 Docket No. 70-1193 Kerr-McGee Nuclear Corporation ATTN:
Mr. W. J. Shelley, Director Regulation and Control Kerr-McGee Center Oklahoma City, OK 73102 Gentlemen:
Enclosed is IE Bulletin No. 79-19, which requires action by you with regard to your NRC license.
Should you have questions regarding this Bulletin or the actions required of you, please contact this office.
Sincerely, b [U.
M'
[ Jacas G. Keppler U
Director
Enclosures:
1.
IE Bulletin No. 79-19 2.
List of Bulletins Issued in Last Six Months cc w/ encl.
Mr. B. E. Brown, General Manager, Manufacturing Central Files PDR Local PDR NSIC 1100 278 79100505F7
a.
Accession No: 7908070515 SSINS No:
6820 UNITED STATES NUCLEAR REGULATORY COMMISSION OFFICE OF INSPECTION AND ENFORCEMENT e WASHINGTON, D.C.
20555 1
t August 10, 1979 IE Bulletin No. 79-19 PACKAGING OF LOW-LEVEL RADIOACTIVE WASTE FOR TRANSPORT AND BUR 7AL Description of Circumstances:
Low-level radioactive vaste is that waste which can be tran_sferred and shipped to one of three waste burial facilities which are located in and licensed by the Agreement States of Nevada, South Carolina, and Washington.
On July 10, 1979, the Governors of the three states notified NRC Chairman Hen,drie of the serious and repeated disregard for rules governing the shipments of low-level radioactive waster, to these burial facilities.
Examples of violations of Agreement State, DOT and NRC rules follow:
Improperly packaged uranium fines igniting packaged liquid scintillation vials in combustible waste is believed to have caused a fire and destruction of a truck at the Beatty, Nevada burial facility on May 14, 1979.
On July 2, 1979, three of twelve steel containers shipped to the Beatty burial facility were found to be leaking radioactive material. The material was described on the bill of lading as being a solid inorganic salt (evaporator concentrates solidified with urea formaldehyde) from a reactor facility.
The Governor of the State of Nevada ordered the drums to be shipped out of the state and the burial facility was temporarily closed.
On July 30, the first shipment into the reopened Beatty facility contained free liquid in " solid" material. The radioactive contents were sand filters used at an insitu leaching process at a uranium mill.
Forty-three shipments with sixty-three deficiencies were observed during the package inspection program between April 10 and July 5, 1979, by the Agreement State of South Carolina, at the Barnwell, S.C. burial facility. The shipments were from reactor, medical, industrial and military facilities.
On June 28, 1979, the Federal Highway Administration issued a Notice of Violation to a reactor facility proposing a $10,000 fine for tr cont @
tion resulting from improper closure for improper loading of the drums, 3UpLICATE DOCUMENT
}/9
?
These are a few examples of ships' facilities which did not fully mes Entire document Previously entered which were developed to protect tt into system nder,.
Governors of the three States with pg[$)
!w that if the situation is not recti ASO
,.v-would deny use of the three burial No. of Paces.