OW Form N A C 418 U S. NUCLEAR REGULATOaY COM*11SSION CERTIFICATE OF COMPLI ANCE 10 CF R 71 For Radioactive Materials Packages 1.tal Certificate Numt;er 1.(b) Revision No.

1.(c) Pacmage toentification No.

1.(c) Pages No. 1.{e) Total No. Pages 0111 1

t!<A / C111/ A 1

1

2. P A E AP.'8 LE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394.173.395, and 173.096 of the Department of Transportation Nazardous Marecials Requiat.ons (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerou-CJrgoes Regulations (46 CF R 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below. meets the safety s.andards set forth in Suboart C of Titte 10. Code of Federal Regulations, Part 71. *' Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportatuan or other applicable regulatory agencies, including the government of any country through or into which the package will be transoorted.

3. This certificate is issued on the basis of a s.nfety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.lb)

Title and identification of report or apolication:

Nuclear Packaging, Incorporated Nuclear Packaging, Incorporated, application 1733 South Fawcett dated March 20, 1978, as supplemented.

Tacoma, Washington 98402 3.tci oocket No.71-9113

4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart O of to CFR 71. as applicable. and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents. Model Number. Fissile Class. Other Conditions, and

References:

(a) Packaging (1) Model No: 7-100 (2) Description A steel encased, lead shielded cask for low specific activity material. The cask is a right circular cylinder 54-1/2 inches high by 84 inches in diameter. The cask cavity is 40-3/4 inches high by 75-1/2 inches in diameter.

The cask side wall consists of a 3/8-inch thick inner steel shell, a 3-inch lead shell, and a 3/4-inch thick outer steel shell. The base is compt sed of two steel plates welded together to form a 5-1/2-inch thick base which is integrally welded to the inner and outer steel shells of the side wall. A st. eel flange is welded to the inner and outer shells of the side wall at the top. The 5-1/2-inch thick lid is comprised of two steel plates, which are stepped and welded to mate with the steel flange. The cask closure is sealed by a gasket located between the lid and s+. eel flange.

Positive closure is accomplished by eight ratchet binders. The lid contains a 6-1/2-inch thick centrally located secondary lid, comprised of three steel plates stepped and welded. The shield plug is sealed by a gasket, and eight 3/4-inch studs and nuts are used to provide positive closure.

A plugged drain line in the base and a stainless steel cavity sleeve is optionally provided.

79082 70 Til

Page 2 - Certificate No. 9113 - Revision No.1 - Docket No. 71-9113 5.

(a) Packaging (Continued)

Tie-down is accomplished by four tie-down lugs welded to the cask body. There are four cask lif ting lugs, three lid lif ting lugs, and one secondary lid lifting lug.

The package gross weight is approximately 42,000 pounds.

(3) Drawing The packaging is fabricated in accordanc'e with Nuclear Packaging Incorporated Crawing No. : BA-20-2000, Revision B, Sheets 1 and 2.

l (b) Contents (1) Type and form of material (i) Greater than Type A quantities of byproduct material contained in process solids, either dewatered, solid or solidified, meeting the requirements for low specific activity radioac-tive material, in secondary containers, or (ii) Greater than Type A quantities of byproduct material contained in solid reactor components that meet the requirements for low specific activity radioactive material.

(2) Maximum quantity of material per package The maximum weight of the contents and secondary containers shall not exceed 7,000 pounds.

Shoring)shall be pieced between the secondary containers (or activated com-6.

ponents and cask cavity to prevent movement during normal conditions of transport.

7.

Lid lifting lugs shall not be used for lifting the cask, and shall be covered in transit; and the secondary lid lifting lug shall not be used for lifting the primary 1id.

8.

The package authorized by this certificate shall be transported on a motor vehicle, railroad car, aircraf t, inland water craft, or hold or deck of a seagoing vessel assigned for the sole use of the licensee.

9.

The drain line shall be appropriately plugged and sealed prior to transport.

10. The packaging authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 171.12(b).
11. Expiration date: May 31, 1983.

Page 3 - Certificate No. 9113 - Revision No.1 - Occke*. No. 71-9113 REFERENCES Nuclear Packaging, Incorporated application dated March 20, 1978.

Supple:nent dated: May 1,1978.

Chem-Naclear Systems, Inc. supplement dated June 29, 1979 FOR THE U. S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety 03 M Date: