Forwards LER 79-011/03L-0
Date released: 10/15/2019 Download: ML19274F044


LER 79-011/03L-0 on 790424:reactor Water Cleanup MO-18 Contactor Failed to Close Manually During Cold Shutdown. Caused by Failure of Auxiliary Contact Mechanism.Repairs Completed Per IE Bulletin 78-05
ML19274F045
Person / Time
Site: Cooper Entergy icon.png
Issue date: 05/23/1979
From: Scheer J
NEBRASKA PUBLIC POWER DISTRICT
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19274F045 (1)
Forwards LER 79-011/03L-0
ML19274F043
Person / Time
Site: Cooper Entergy icon.png
Issue date: 05/23/1979
From: Lessor L
NEBRASKA PUBLIC POWER DISTRICT
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19274F043 (2)