CHOOSE SENSITIVITY FROM DROP DOWN MENU October 3, 2019 Mr. Wren Fowler Director, Licensing NAC International, Inc.
3930 East Jones Bridge Road, Suite 200 Norcross, GA 30092
SUBJECT:
REVISION 69 OF CERTIFICATE OF COMPLIANCE NO. 9225 FOR THE MODEL NO. NAC-LWT PACKAGE
Dear Mr. Fowler:
As requested by your application dated July 16, 2019, (Agencywide Documents Access and Management System ML19199A1312), enclosed is Certificate of Compliance No. 9225, Revision No. 69, for the Model No. NAC-LWT transportation package. Changes made to the enclosed certificate are indicated by vertical lines in the margin. The staffs safety evaluation report is also enclosed.
The approval constitutes authority to use the package for shipment of radioactive material and for the package to be shipped in accordance with the provisions of Title 49 of the Code of Federal Regulations (49 CFR) 173.471. Those on the attached list have been registered as users of the package under the general license provisions of 10 CFR 71.17 or 49 CFR 173.471.
OFFICIAL USE ONLY - SECURITY-RELATED INFORMATION Upon Removal of, this document is uncontrolled
CHOOSE SENSITIVITY FROM DROP DOWN MENU CHOOSE SENSITIVITY FROM DROP DOWN MENU If you have any questions regarding this certificate, please contact me or Bernard White of my staff at (301) 415-6577.
Sincerely,
/RA/
John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Docket No. 71-9225 EPID No. L-2019-RNW-0020
Enclosures:
- 1. Certificate of Compliance No. 9225, Rev. No. 69
- 2. Safety Evaluation Report
- 3. Registered Users cc w/encls. 1& 2: R. Boyle, DOT J. Shuler, U.S. DOE c\\o L. F. Gelder Registered Users
CHOOSE SENSITIVITY FROM DROP DOWN MENU CHOOSE SENSITIVITY FROM DROP DOWN MENU
SUBJECT:
REVISION 69 OF CERTIFICATE OF COMPLIANCE NO. 9225 FOR THE MODEL NO. NAC-LWT PACKAGE, DOCUMENT DATED: October 3, 2019 DISTRIBUTION: (Closes EPID No. L-2017-NEW-0009)
DSFM r/f NMSS r/f D. Marcano C. Regan MLayton A. Dimitriadis, RI B. Bonser, RII M. Kunowski, RIII J. Katanic, RIV, G. Warnick, RIV Docket No. 71-9225 Closes EPID No. L-2019-RNW-0020 G:\\SFST\\PART 71 CASEWORK\\Model NAC-LWT Docket 71-9225\\9225.r69 Letter and SER.docx G:\\SFST\\PART 71 CASEWORK\\Model NAC-LWT Docket 71-9225\\9225.r69.docx ADAMS Package No.: ML19274C593 CoC Accession No. ML19274C595 Letter/SER Accession No. ML19274C597 OFFICIAL RECORD COPY OFC:
NMSS/DSFM NMSS/DSFM NMSS/DSFM NAME:
BWhite SFigueroa JMcKirgan DATE:
9/26/19 9/27/19 10/3/19
CHOOSE SENSITIVITY FROM DROP DOWN MENU SAFETY EVALUATION REPORT Docket No. 71-9225 Model No. NAC-LWT Package Certificate of Compliance No. 9225 Revision No. 69 Evaluation By letter dated July 16, 2019, (Agencywide Documents Access and Management System ML19199A1312), NAC International, Inc. (NAC), requested renewal of Certificate of Compliance No. 9225 for the Model No. NAC-LWT transportation package. NAC did not request any changes to the package design, operating procedures, or acceptance tests and maintenance program.
In support of this application, NAC submitted a partial consolidated application, in that the page changes submitted for Revision 45 of the application consolidated the supplements dated October 19, 2015 and October 14, 2016; December 23, 2016, May 15, 2017, May 18, 2017, August 2, 2017, and October 10, 2017, but not the application dated August 18, 2015.
In the consolidated SAR, NAC incorporated all supplements previously approved by U.S.
Nuclear Regulatory Commission (NRC). The staff also reviewed the operating and maintenance procedures for the package and found them to be adequate.
CONDITIONS Condition 20 was revised to authorize use of Revision No. 68 until April 30, 2020.
Condition No. 22 was revised to reflect the new expiration date of April 30, 2025.
The references section has been updated to include the application and supplements were clarified to indicate which certificate holder submitted them.
CONCLUSION Based on the statements contained in the application, and the conditions listed above, the staff concludes that the changes indicated do not affect the ability of the package to meet the requirements of 10 CFR Part 71.