Commonwealth Edison One First National Piara Chicago Ilknors p

Adoress Repty to Post Office Box 767 Chicago. Ilhnois 60690 s

May 10, 1979 Mr. James G. Keppler, Director Directorate of Inspection and Enforcement - Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

LaSalle County Station Units 1 and 2 Response to IE Bulletin No. 79-03

" Longitudinal Weld Defects in ASME SA-312 Type 304 Stainless Steel Pipe Spools Manufactured by Youngstown Welding and Engineering Company" NRC Docket Nos. 50-373 and 50-374 Reference (a):

J. G. Koppler letter to B.

Lee, Jr.

dated March 12, 1979

Dear Mr. Keppler:

Reference (a) transmitted IE Bulletin 79-03 regarding welding defects in certain longitudinally welded pipe spools.

In accordance with that bulletin, we have reviewed the LaSalle County 51ation piping specifications and supplied material and determined the following:

1.

Only seamless ASME SA-312 or electric-fusion welded ASME SA-358 is permitted to be used in safety-related systems.

2 Piping supplied for the NSSS does not contain SA-312 material.

3.

Piping supplied for balance of plant aafety-related systems does not contain questionable SA-312 material from Youngstown Welding and Engineering Co.

2353 143 7906W0

Commonwealth Edison NRC Docket Nos. 50-373/374 Mr. James G. Keppler:

2-May 10, 1979 r

Based on this review, we conclude that ASME SA-312 stainless steel pipe welded without filler metal manufactured by Youngstown Welding and Engineering Company is not in use or planned for use in safety-related systems at LaSalle County Station Units 1 and 2.

Please address any questions you may have concerning this matter to this office.

Very truly yours, Cordell Reed Assistant Vice-President cc:

Director, Division of Reactor Construction Inspection 2353 144 m