ML19273B881

From kanterella
Jump to navigation Jump to search
Forwards IE Info Notice 79-12, Attempted Damage to New Fuel Assemblies. No Written Response Necessary
ML19273B881
Person / Time
Site: 05000106, Oregon State University
Issue date: 05/10/1979
From: Engelken R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To: Popovich M
Oregon State University, CORVALLIS, OR
References
NUDOCS 7906180451
Download: ML19273B881 (1)


Text

  1. "

4, UNITED STATES 4

yg NUCLEAR REGULATORY COMMISSION S,f4 REGION V

,.zpg g

SulTE 202, W ALNUT C HEEK PLAZ A 4

,O' 1990 N. C ALIFORNIA BOULEVAPD 9 *eee#

W ALNUT CREEK. C ALIFORNI A 94596 May 10, 1979 i

Docket No. 50-243 50-106 Oregon State University Radiation Center Corvallis, Oregon 97331 Attention:

M. popovich, Vice president Administration Gentlemen:

This Information Notice is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability to their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have any

~

questions regarding this matter, please contact the Director of the appropriate NRC Regional Office.

Sincerely, v aingelkpn w

ireEtor Y'c/'

Enclosure:

IE Infonnation Notice No. 79-12 2354 210 790618045/

.z

. O;.,

UNITED STATES NUCLEAR REGULATORY COMMISSI0I1 0FFICE OF INSPECTION AtlD ENFORCEMENT 20555 May 10, 1979 IE Information Notice No. 79-12 ATTEMPTED DAMAGE TO HEW FUEL ASSEMBLIES This Notice provides information concerning the surreptitous introduction of a possibly damaging liquid into the new fuel storage pool at the Virginia Electric and Power Company, Surry Power Station in Surry County, Virginia.

On Monday, May 7,1979, while conducting inspections of new fuel for Unit 2, the licensee found that plastic protective liners on 62 of 64 assemblies had been tampered with.

Further inspection revealed that a white crystalline substance had been poured onto the assemblies.

Preliminary analysis by VEPC0 indicates that the substance is sodium hydroxide. The new fuel is stored in the fuel Building, an area which is locked and alarmed, and to which access is controlled by the issuance of specially coded access cards.

These cards are issued after the successful completion of a background screening program for both Virginia Electric and Power Company and contractor personnel.

The FBI is presently on-site conducting an extensive investigation.

Westinghouse, the fuel vendor, is assisting in the evaluation of possible fuel damage.

This event could possibly provoke similar behavior on the part of other persons. Consequently, you should be aware of such an eventuality. At this time the NRC is not placing additional requirements on you, but is advising that extra caution be exercised in your existing security program.

This Information Notice is provided as an early notification of a possibly significant matter.

It is expected that recipients will review the information for possible applicability of their facilities.

No specific action or response is requested at this time.

If further NRC evaluations so indicate, an IE Circular or Bulletin will be issued to recommend or request specific licensee actions.

If you have questions regarding the matter, please contact the Director of the appropriate NRC Regional Office.

No written response to this Information Notice is required.

2354 211

Enclosure:

List of IE Information 7906060161 Notices Issued in 1979 1 of 1

Infonnation flotice flo. 79-12 Enclosure May 10, 1979 Page 1 of I LISTillG OF IE IflFORMATI0fl fl0TICES ISSUED Ifl 1979 IrlFORMATIO:1 Subjec t Date Issued To flotice flo.

Issued 79-01 Bergen-Paterson liydraulic 2/2/79 All power reactor Shock and Sway Arrestor facilities with an OL or a CP 79-02 Attempted Extortion -

2/2/79 All Fuel facilities Low Enriched Uranium 79-03 Limitorque Valve Geared 2/9/79 All power reactor Limit Switch Lubricant facilities with an OL or a CP 79-04 Degradation of 2/16/79 All power reactor Engineered facilities with an Safety Features OL or a CP 79-05 Use of Improper Materials 3/21/79 All power reactor in Safety-Related Components facilities with an OL or CP 79-06 Stress Analysis of 3/23/79 All llolders of Safety-Related Piping Reactor OL on CP 79-07 Rupture of Radwaste Tanks 3/26/79 All power reactor facilities with an OL or CP 79-08 Interconnection of 3/28/79 All power reactor Contaminated Systems with facilities with an Service Air Systems used OL and Pu Processin9 As the Source of Breathing fuel facilities Air 79-09 Spill of Radioactively 3/30/79 All power reactor Contaminated Resin facilities with an OL 79-10 flonconforming Pipe 4/16/79 All power reactor Supp' art Struts facilities with a CP 2354 212