1 b

ut;s t t o sT Aits f

[#

flUcLEAR nEGULATOfiY COM'!ISSION 4

af f

~2.fI h WASHINGTON, D. C. 20355 V/

MAY 3IM

+....

MEMORANDUM FOR:

A. Schwencer, Chief, Operating Reactors Branch #1, D0R FROM:

G. Lainas, Chief, Plant Systems Branch, 00R I

SUBJECT:

SAFEYY EVALUATION REPORT - PRAIRIE ISLAND NUCLEAR GENERATING PLANT, UNITS 1 AND 2 - EVALUATION OF l

SAFETY INJECTION SYSTEM ACTUATION TECHNICAL SPECIFICATION CHANGE REQUEST (TACS 11634/11635) i The Plant Systems Branch has reviewed Northern States Power Company's submittal of April 26, 1979 in which the licensee requested amendments to Facility Operating Licenses DPR-42 and DPR-60 to incorporate changes to the Technical Specifications for the Prairie Island Nuclear Generating Plant, Unit; 1 and 2.

The proposed change is the result of a modification proposed in response to the directions of IE Bulletin No.79-06A dated April 14, 1979.

l l

The amendments proposed changes to the Technical Specifications which j

relate to modifications to the Safety Injection (SI) actuation system logic.

The design change requested is thet an SI signal be developed i

by a two-of-three low pressurizer pressure signal instead of a one-of-i three coincidence of low pressurizer pressure and level signal.

Based on our review, we conclude that the modifications to the SI actuation system logic satisfy the requirements of IEEE 279-1971 and that the associated Technical Specifications are correct; and therefore, are acceptable.

"b Chigf G. La ng Plant 59, e,ms Branch Division of Operating Reactors cc:

See next page 2350 164 79061200 %

Contact:

J. Burdoin X-28077 cc w/ enclosure:

V. Stello D. Eisenhut S. Hanauer R. Satterfield R. Vollmer M. Grotenhuis D. Tondi J. Burdoin 2350 165

.