Text
Enclosure 4 to E-55004 Listing of Computer Files Contained in Enclosure 5 Disk ID No. (size)
Discipline System/Component File Series (topics)
Number of Files Enclosure 5
One Computer Hard Drive Total (67.7 GB)
Structural (67.7 GB)
Structural MP197HB Impact Limiter Drop Evaluation Appendix A.13.18.2.1 (Sensitivity Analysis
- 1, Figure A.2.13.18-1 with all bolts)
Folder: Sensitivity Analysis # 1 (All Bolts)
- Input and Output LS Dyna files for bounding Slap Down 10º case with all bolts.
415 Structural MP197HB Impact Limiter Drop Evaluation Appendix A.13.18.2.1 (Sensitivity Analysis
- 1, Figure A.2.13.18-1 with high stress bolts removed)
Folder: Sensitivity Analysis # 1 (High Stress Bolts Removed)
- Input and Output LS Dyna files for bounding Slap Down 10º case with high stress bolts removed.
415 Structural MP197HB Impact Limiter Drop Evaluation Appendix A.13.18.2.2 (Sensitivity Analysis
- 2, Table A.2.13.18-1, Detailed Model)
Folder: Sensitivity Analysis # 2 (Detailed Bolt Model)
- Input and Output LS Dyna files for bounding Slap Down 10º case with detailed bolt model.
1815 Page 1 of 1