ML19270H028

From kanterella
Jump to navigation Jump to search
Forwards LER 79-061/03L-0
Date released: 10/11/2019 Download: ML19270H028


LER 79-061/03L-0 on 790518:control Room Emergency Damper HV5311A Stuck in Open Position During Surveillance Testing. Caused by Humidity Corroding Brass Bushings of Shaft.Damper Repaired & Humidifiers Relocated
ML19270H030
Person / Time
Site: Davis Besse 
Issue date: 06/14/1979
From: Rudolph J
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19270H030 (3)
Forwards LER 79-061/03L-0
ML19270H027
Person / Time
Site: Davis Besse 
Issue date: 06/14/1979
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19270H027 (1)