ML19270G893

From kanterella
Jump to navigation Jump to search
Notice of Deviation from Insp on 790226-0302
ML19270G893
Person / Time
Issue date: 03/16/1979
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To:
Shared Package
ML19270G887 List:
References
REF-QA-99900036 99900036-79-1, NUDOCS 7906210083
Download: ML19270G893 (1)


Text

,

Combustion Engineering Inc.

Docket No. 99900036/79-01 NOTICE OF DEVIATION Based on the results of an NRC inspection conducted on February 26 -

March 2,1979, it appeared that certain of your activities were not conducted in full compliance with NRC requirements as indicated below:

Criterion V of Appendix B to 10 CFR 50 states in part that " Activities affecting quality shall be prescribed by documented instructions, proce-dures, or drawings, of a type appropriate to the circumstances and shall be accomplished in accordance with these instructions, procedures, or drawings...."

In addition, weld specification GTA 1.1.-100-0 requires welding to be accomplished between 90 to 110 amps.

Contrary to the above requirements, it was observed that welding to specification GTA 1.1.-100-0 on an "eggerate assembly" identified by heat No. NX 8362-D and contract No. 72273 was being accomplished with 136 amps.

2240 198

~