yo A 8181 E liith STilEET IHAYER Tul_sA. OuAnOuA 7nu l'IIONE l-918-tiG3-5505 INSPECTION SERVICE, INC.
PD %
May 9, 1979 L
Mr. Charles E.
MacDonald, Chief Transportation Branch Division of Puel Cycle & Material Safety Uni.ted States Nuclear Regulatory Commission Washington, D.
C.
20555
Dear Mr. MacDonald:
RE: Docket No. 71-0145 J
This letter and enclosures is in response to your letter received April 13, 1979, reauesting additional information in regard to our Part 71 Quality Assurance Program.
Please find enclosed seven copies of our revised page of our Part 71 Ouality Assurance Program as requested.
Should you have additional needs, they will receive our immediate attention.
Sincerely, Thayer Inspection Service, Inc.
k a-<-
Donald W. Thayer-2270 350 President 1:nc los u res :
7 906 2 0 G.774 4 12359 N-il AY
- GAMM A II AY
- M AGNETIC l'AllTICI.E
- l'I.TilASONIC
- DYE l'ENETilANT
- CONSUI.TATION
e AUDITS 1.
Established schedules of audits of the Quality Assurance Program will be performed using written checklists.
2.
Results of audits will be maintained and reported to the management.
3 Audit reportu will be evaluated and deficient areas will be correc ted.
1 The audits will be dependent on the safety significance 4
of the activity being audited, but each ac tivity will be audited at least once a year.
5, Audit reports will be maintained as part of the quality a usura nc e records.
Revision 5/9/79 6.
The auditor (s) will have no responsibility in the acti vity they audit.
2270 251 J th m