ML19269E918
| ML19269E918 | |
| Person / Time | |
|---|---|
| Site: | 07001201 |
| Issue date: | 05/22/1979 |
| From: | Ketzlach N NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | Zeff D BABCOCK & WILCOX CO. |
| References | |
| NUDOCS 7906290818 | |
| Download: ML19269E918 (3) | |
Text
, ",f*l'%e,'o,
+
UNITED STATES
!})e "h NUCLEAR REGULATORY COMMISSION E
WASHINGTON,0. C. 20555
- .g
%; v.....f
!<1AY 3 21979 FCPF:NK 70-1201
' bhM-iioc Babcock & Wilcox Company Commercial Nuclear Fuel Plant ATTN: Mr. D. W. Zeff, Manager Safety, Licensing and Safeguards P. O. Box 1260 Lynchburg, Virginia 24505 Gentlemen:
This is to confirm our telephone conversation of May 9,1979 regarding your revised amendment application dated April 30, 1979. As we dis-cussed, your revised application did not address all our comments on your original application which were transmitted by letter dated December 17, 1978. The outstanding coments on your application are attached as an enclosure to the letter.
In order to meet our schedule for completion of the review of your amendment application, your response to the requested additional infor-mation should be received within 30 days after the date of this letter.
' Sincerely, h
Norman Ketzlach Uranium fuel Fabrication Section Fuel Processing & Fabrication Branch Division of Fuel Cycle and Material Safety
Enclosure:
As stated 79062 g g\\g Sk 9
ENCLOSURE COMMENTS Ofl REVISED B&W COMMERCIAL fiUCLEAR FUEL PLA?4T AMEt10MEf!T APPLICATI0tl DATED APRIL 30,1979 I.
Section IV Appendix 1 1.
Page 3 The action level for clean-up activities of removable a contamination in controlled areas shall be 5,000 dpm/
2 100 cm.
2.
Page 4 The survey frequency, item 3.c., shall include daily surveys of the cafeterias and locker rooms.
2 3.
The maximum total a (item 5.b.) shall be < 7,500 dpm/50 cm,
II.Section V 1.
Page 78 The maximum total a (item 8.1.3.a.) contamination will not 2
exceed 7,500 dpm/50 cm,
2.
Page 91 Since removal of page 30 is requested, the requirement for daily calibration checks on laboratory counting instruments when in use must be included in the license conditions.
3.
Page 94(a)
Remove the first paragraph of part 8.4.4.1.a. (continued) on survey of hands.
It is covered on page 93, part 8.4.4.
Page 94(b)
The action level for removable contamination in the controlled 2
area shall be 5,000 dpm/100 cm,
Page 94(c)
Remove "(Except cafeteria and locker rocms shall be weekly)"
from the survey frequency for clean areas and replace it with a separate paragraph as follows:
2142 206
- " Lunchrooms and locker rooms shall be surveyed daily and removable contamination kept as low as reasonably achievable."
4.
Page 95a The " Receiving Inspection" requirement, Part 8.5.1, should remain as part of the license.
2142 207
_