ML19269E858

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5805,Revision 8,for Model Atcor Vndb Cask
ML19269E858
Person / Time
Site: 07105805
Issue date: 06/05/1979
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19269E597 List:
References
NUDOCS 7906290734
Download: ML19269E858 (5)


Text

_.

Form NRC418 U.S. NUCLE AR REGULATORY COMMISSION U

CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materia;s Packages 1.(a) Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages 9POR R

fl< A /99n4 /R ( IF 1

5

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394.173.395, and 173.396 of the Department of Transportation Hazardous Materia Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146--149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Meterial Under Certain Canditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of art or application:

Chem-Nuclear Systems, Inc.

ATCOR, Incorporated application dated P.O. Box 1866 April 3,1974, as supplemented Bellevue, WA 98009 3.(c)

Docket No. 7] _ gppg 4, CONDITIONS This certifics:e is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the condi: ions specified in item 5 below.

5. Description of Packaging and Autnorized Contents, Model Number, Fissile Class Other Conditions, and

References:

(a) Packaging (1) Model No.: Vandenburgh Cask (2) Description The package is a steel-encased, lead-shielded cask with crushable impact limiters. The basic cask is a steel cylinder 133-3/4 inches long by 50-1/2 inches in diameter with maximum cavity dimensions of 36 inches in diameter by 116 inches long.

Shielding is pro-vided by 6 inches of chemical lead in the sides and closure base plate and 5-1/4 inches in the closed end.

The outside ste?l encasement is made up of two, 1/2-inch plates on the sides and tcree plates totaling 2-5/8 inches on the end.

The containment vessel is a 1/4-inch thick cylinder with a 1/2-inch end plate. The shells are welded together with the lead shielding poured to fill the annular and end spaces.

The removable, flanged and recessed base plate weldment consists of 0.38-inch and 1-1/4-inch outside plates and a 1/2-inch inside plate.

The space between the plates is lead-filled.

The base plate is secured to the cask body by means of twelve, 1-1/2-inch high strength bolts and nuts and sealed with two silcone gaskets.

2}f6 Q[g 7906290 73p c

i

\\

6 Page 2 - Certificate No. 5805 - Revis'on No. 8 - Docket No. 71-5805 5.

(a) Packaging (continued).

(2) Description (continued)

The cavity is penetrated by a vent line at the closed end and a drain line through the base plate.

The vent line is sealed by a gasketed and shielded plug. The drain line is sealed with a 25 psig vent valve.

Cask appendages include two, 8-inch lifting trunnions and two, 4-inch removable tilting trunnions of the cask side.

Removable impact limiters are provided at the cask ends and at the two, 8-inch trunnions. The former consist of a series of 6-inch diameter closed and tubes.

Each impact limiter has tubes approxi-mately 6 inches long around the end periphery. The closure end impact limiter has 12 tubes, six about 6 inches long and six about two inches long, around the sides. The closed end impact limiter has six tubes about 6 inches long around the sides. A gusseted tube acts as the trunnion impact limiter.

The cask is secured horizontally to a skid which is mounted to the transport vehicle for shipment. A sunshade is provided.

The gross weight of the package, excludirig the skid and sunshade is approximately 70,000 pounds. The skid weighs about 4,200 pounds.

(3) Drawings The Vandenburgh Cask is described by BMI Drawing.No. MOD 100, Rev. E; and ATCOR Drawings Nos.: MOD 139-1, Rev. E; MOD 140, Rev. A; 0990-D-1, Rev. F; 0999-D-02, Rev. G; 0999-D-03, Rev. H; 0999-0-04, Rev. B; 0999-D-07, Rev. G; 0818-D-01, Rev. A; 1000-D-0024-0, Rev. 0; and 0648-D-0001.

5.

(b) Contents (1) Type and form of material (i)

Irradiated stainless steel shroud cans, or miscellaneous non-fissile or fissile exempt irradiated components packaged in secondary containers.

(ii) Irradiated BWR uranium oxide fuel assemblies. The minimum cooling time of each assembly shall be 365 days. Prior to irradiation, the fuel assemblies shall have the following dimensions and specifications:

Fuel form Clad UO2 pellets 2146 080

Page 3 - Certificate fio. 5805 - Revision flo. 8 - Docket tio. 71-5805 5.

(b) Contents (continued).

(1) Type and form of material (continued)

Cladding material Stainless Steel Maximum U content, kg 1 21.1 Maximum U-235 enrich 3.94 ment, w/o Maximum bundle cross section, sq. in.

5.63 Fuel pin array 10xl0 Fuel diameter, in.

0.351 Maximum active.~Jel length, in.

83.3 (2) Maximum quantity of material per package (i). For the' contents described in 5(b)(1)(i):

47,140 curies total, with a pcckage intet.ial decay heat lead not to exceed 800 watts.

(ii) For the contents described in 5(b)(1)(ii):

Maximum package decay heat shall not exceed 3,500 watts.

In any given foot of the fuel assembly, the average linear heat generation rate (averaged over all the rods within that foot of the assembly) shall not exceed 9.1 kw/ft per rod during irradia-tion within the reactor core.

Eight (8) BWR fuel assemblies with a maximum burnup of each assembly not to exceed 12,000 MWD /MTU and with a centrally located poison rod as shown in ATCOR Drawing flo. 0999-D-01, Rev. F or Seven (7) BWR fuel assemblies with a maximum burnup of each astambly not to exceed 14,000 MWD /MTV ard with a centrally located poison rod as shown in ATCOR Drawing I;o. 0999-D-01, Rev. F, or Six (6) B"R fuel assemblies with a maximum burnup of each assembly not to exceed 16,000 t&lD/MTU and with a centrally located poison rod as shown in ATCOR Drawing No. 0999-D-01, Rev. F.

2146 071

Page 4 - Certificate No. 5805 - Revision No. 8 - Docket No. 71-5805 5.

(b) Contents (continued)

(c) Fissile Class III For the contents described in 5(b)(1)(ii) and limited in 5(b)(2)(ii):

Maximum number of packages per shipment One (1) package 6.

For the contents described in 5(b)(1)(i), and limited in 5(b)(2)(i):

(a) Both the inner cask cavity and the secondary container shall be free of water when the package is delivered to a carrier for transport.

(b) Shoring shall be placed between contents, secondary container and cask cavity to minimize secondary impacts due to accident sequence.

(c) The maximum gross weight of the contents, secondary container and shoring is limited to 9,220 pounds.

7.

For the contents described in 5(b)(1)(ii), and limited in 5(b)(2)(ii):

(a) The containment cavity shall be equipped with a vent valve, either Teledyne Republic Manufacturing Model No. 684-2-3/4-SS with a stainless steel teat or Circle Seal Products Model No. D520T-6M-25. The valve settinc is to be 25 psig +10,.

- 0*

(b) For less than 8 fuel assemblies, empty fuel canisters shall be placed in the fuel basket.

(c) The poison tube and canister shall be maintained in the central position of the fuel basket.

(d' The poison rod annulus shall be filled with a homogeneous mixture of BuC and sand. The mixture shall contain a minimum of 80% BuC by volume.

(e) Periodic tests, inspections and maintenance of the cask shall be performed in accordance with the plan outlined in Section III-2 (Vandenburgh Cask Inspection and Preventive Maintenance) of the application, Pevision C, April 23, 1976.

(f) Cask loading und unloading shall be performed in accordance with the procedures outlined in Section III-l (Vandenburgh Cask Handling Procedures -

LACSWR Fuel) of the application, Revision C, April 23, 1976.

(g) The maximum gross weight of the contents is limited to 10,800 pcunds.

8.

The containment vessel (base plate and vent plug) shall be sealed with silicon 0-rings.

2146 082

.-l i

Page 5 - Certificate No. 5805 - Revision No. 8 - Docket No. 7115805 9.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

~

10.

Expiration date:

December 31, 1980.

REFERENCES ATCOR, Incorporated's application dated April 3,1974.

Supplements dated: July 23, 1974; August 15, October 9, and December 2,1975; April 29, and August 30, 1976; and January 24 and May 17, 1979.

l FOR THE U.S. NUCLEAR REGULATORY COMMISSION RNO

(_gc-Charles E. MacDonald, Chief j

Transportation Branch Division of Fuel Cycle and Material Safety Ette:

JUN 0 51979

'N e

e 2146 083

....