ML19269E313

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 79-07.No Computer Codes Identified by S&W Which Used Any of Methods Described in Item 1.NUPIPE 03/01-03/10 Computer Code Used in Seismic Stress Analysis of safety-related Piping
ML19269E313
Person / Time
Site: Beaver Valley
Issue date: 05/16/1979
From: Woolever E
DUQUESNE LIGHT CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 7906270203
Download: ML19269E313 (1)


Text

4 au 3g Yf A

(412) 471-4300 435 Sixth Avenue Pittsburgh, Pennsylvania 15218 May 16, 1979 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pennsylvania 19406 ATTENTION:

MR. BOYCE H. GRIER, DIRECTOR

SUBJECT:

Beaver Valley Power Gtation Unit No. 2 Docket No. 50-412 IE Bulletin No. 79-07 Seismic Stress Analysis of Safety-Related Piping Gentlemen:

IE Bulletin 79-07 requested certain information conccrning seismic analysis of safety-related piping.

The following is our response to this bulletin.

In response to Items 1, 2 and 4 no computer codes have been identified by Stone and Webster which used any of the methods described in Item 1 of the bulletin.

In response to Item 3, the following computer program was used in the seismic stress analysis of safety-related piping for Beaver Valley Unit No. 2.

NUPIPE 03/01 through 03/10 Verification of computer program (NUPIPE 03/10) used by Stone and Webster is being addressed in response to the April 2 Addendum to the March 13 Order to Show Cause for Beaver Valley Power Station Unit No. 1.

Stone and Webster's in-house benchmarking links all major versions of NUPIPE to Version 03/10.

DUQUESNE LIGHT COMPANY By E.V J.' Woolever Vice Presi' dent COPIES TO:

Dr.

E. Volgenau (15)

Mr. W. G. Mcdonald (1) 213-1 194

.t 90627 0 735