ML19269E056
| ML19269E056 | |
| Person / Time | |
|---|---|
| Site: | Nuclear Energy Institute, 99902028 |
| Issue date: | 09/26/2019 |
| From: | Ashkeboussi N Nuclear Energy Institute |
| To: | Ross-Lee M Document Control Desk, Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML19269E054 | List: |
| References | |
| Download: ML19269E056 (2) | |
Text
NIMA ASHKEBOUSSI Director, Fuel Cycle Programs Fuel and Radiation Safety 1201 F Street, NW, Suite 1100 Washington, DC 20004 P: 202.739.8022 nxa@nei.org nei.org September 26, 2019 Ms. Mary Jane Ross-Lee Acting Division Director Division of Licensing Projects Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555-0001
Subject:
Transmittal of EPRI Benchmark Revision 1-A, Utilization Revision 2, Utilization Revision 2-A, and NEI 12-16, Revision 4 Project Number: 689
Dear Ms. Ross-Lee:
On behalf of the Nuclear Energy Institutes (NEI) 1 members and Electric Power Research Institute (EPRI),
we are submitting the approved and published versions of the EPRI technical reports Benchmarks for Quantifying Fuel Reactivity Depletion Uncertainty - Revision 1-A and Utilization of the EPRI Depletion Benchmarks for Burnup Credit Validation - Revision 2-A. These reports incorporate the NRC final safety evaluation report (ML19189A111) and transmittal letter (ML19189A112). Additionally, the reports contain historical review information consisting of the NRC requests for additional information (RAIs) and responses to RAIs as appendices. The EPRI benchmark report also contains the quality assurance letter in Appendix H.
In addition to the published EPRI reports, we are submitting a revision to NEI 12-16, Guidance for Performing Criticality Analyses of Fuel Storage at Light Water Reactor Power Plants and Utilization of the EPRI Depletion Benchmarks for Burnup Credit Validation - Revision 2 that have been updated to incorporate the proposed changes resulting from the NRC Public Meeting on December 20th, 2018. These changes ensure consistency between NEI 12-16 and the EPRI technical reports. The changes to NEI 12-16 and the EPRI technical report are as noted in Attachment 3 to NEIs January 2019 letter (ML19196A276).
We look forward to working with the NRC on the implementation of this important component of the regulatory framework. The use of this guidance will support the continued assurance of spent fuel pool criticality safety 1
The Nuclear Energy Institute (NEI) is responsible for establishing unified policy on behalf of its members relating to matters affecting the nuclear energy industry, including the regulatory aspects of generic operational and technical issues. NEIs members include entities licensed to operate commercial nuclear power plants in the United States, nuclear plant designers, major architect and engineering firms, fuel cycle facilities, nuclear materials licensees, and other organizations involved in the nuclear energy industry.
Ms. Mary Jane Ross-Lee September 26, 2019 Page 2 and improve the efficiency in the preparation and review of licensing documents involving spent fuel pool criticality analysis. Please contact me if you have any questions or require additional information.
Sincerely, Nima Ashkeboussi : EPRI Benchmarks for Quantifying Fuel Reactivity Depletion Uncertainty - Revision 1-A (3002016035) - https://www.epri.com/#/pages/product/000000003002016035/ : EPRI Utilization of EPRI Depletion Benchmarks for Burnup Credit Validation - Revision 2-A (3002017254) - https://www.epri.com/#/pages/product/000000003002017254/ : EPRI Utilization of the EPRI Depletion Benchmarks for Burnup Credit Validation - Revision 2 (3002016888) - https://www.epri.com/#/pages/product/000000003002016888/ : NEI 12-16, Revision 4 c: Mr. Robert Lukes, NRC/NRR Mr. Dennis Morey, NRC/NRR Mr. Jason Drake, NRC/NRR Document Control Center, NRC Mr. Jeremy Renshaw, EPRI Ms. Hatice Akkurt, EPRI Ms. Tina Taylor, EPRI