University o f Wisconsin 5!!!^32AliMEiiiIiik"'

9515 =::=- "-~-

February 5, 1979 Director of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20545 Re:

Docket 50-156, License R-74; Reply to January 29, 1979 letter from Robert W. Reid, Chief Operating Reactor Branch #4

Dear Sirs:

235 The requested 17.8 Kg of contained U license limit will be allocated as shown in the table below. The table also includes the 16 grams of Plutonium and 135.4 grams of 93% enriched Uranium contained in MTR-type fuel plates also allo-cated in the present license.

Since the total amount of SNM to be received is greater than 5 Kg, the refueling plan is that six 4-element bundles will be received, loaded into the core, and operated to self-protecting levels before receipt of the final portion of the shipment. The maximum amount of non-exempt SNM on hand at any time will be the period between receipt of the final shipment of FLIP fuel and bringing four of the additional FLIP bundles to 10 CFR 73.6(b) self-protection levels.

The table below shows SNM status at present, at the maximum non-exempt level, and then the expected normal operating levels.

Items U

Content

% Enriched Exempt St.stus (a) Presently on Hand:

(1) 32 TRIGA Fuel Bundles 4.233 19.30 Exempt 10 CFR 73.6(a)

(2) 15 FLIP Fuel Bundles 7.195 69.79 Exempt 10 CFR 73.6(b)

(3) MTR Fuel Plates 0.135 93.22 Not Exempt (4) Fission Detectors 0.009 93.00 Not Exempt (5) PuBe Neutron Source 16 Grams Pu Not Exempt Total on Hand 11.572 Kg U

16 grams Pu; 11.428 Kg Uranium Exempt 169 Pu and 144 Uranium grams Not Exempt (b)(1) Maximum non-exempt condition -- after final shipment of six FLIP bundles plus two spare instrumented elements Items 1, 3, 4, and 5 same as (a) 790212o( O

r Director of Licensing V. S. fluclear Regulatory Commission February 5,1979 35 (b)

U Content

% Enriched Exempt Status (2) 27 FLIP bundles + 2 Instrumented Elements 13.495 fiominal 70 10.219 Exempt 10 CFR 73.6(b) 3.276 flot Exempt Totals 18.872 Kg U

+ 16 3. oms Pu 235 235 ( 4.233 Kg U by 10 CFR 73.6(a)

Exempt: 14.452 Kg U (10.219 Kg U235 by 10 CFP, 73.6(b) 2 Not Exempt: 3.420 Kg U

+ 169 Pu (c)(1) After completion of core test program for all-FLIP fueled core --

Items 1, 3, 4, and 5 same as (a)

(2) 25 FLIP Bundles (core) 12.235 flominal 70 Exempt 10 CFR 73.6(b) 2 FLIP Bundles (spares) 1.008 flominal 70 Not Exempt 2 FLIP Instrumented Elements (Spares) 0.252 fiominal 70 flot Exempt Totals 18.872 Kg U 35 + 16 grams Pu 235 Exempt: 16.468 Kg( 4.233 Kg U by 10 CFR 73.6(a) 235 (12.235 Kg U by 10 CFR 73.6(b) flot Exempt: 1.404 Kg U 35 + 16 grams Pu We hope the information provided will enable prompt processing of our requests for license amendment.

Very truly yours,