APPENDIX A
, NOTICE OF VIOLATION Nuclear Fuel Services, Inc.
Docket No. 50-201 Based on the results of an NRC inspection on November 15-17,1978, it appears that certain of your activities were not conducted in full com-pliance with NRC regulations and the nditions of your license as indicated below.
Item A is an Infrat son.
Item B is a Deficiency.
A.
Technical Specifications 7.1.4 states " Detailed written procedures...
shall be provided for operation of the plant.
In addition, proce-dures for handling abnormal operating conditions, and for radiation protection shall be provided."
Section 8.0 of the Health and Safety Procedures Manual, developed pursuant to Technical Specification 7.1.4, requires routine surveys be made on a scheduled frequency.
Contrary to the above, Section 8.0 of the Health and Safety Manual was not followed in the following instances:
1.
Weekly smear surveys for alpha contamination were not per-formed in the Instrument Shops as required by Table 8.15(b) during 1978.
2.
Quarterly smear surveys for alpha contamination were not per-formed in the Annex Building as required by Table 8.17 during 1978.
3.
Weekly beta-gamma radiation surveys were not performed in the Emission Spec Laboratory, or the Mass Spec Laboratory as required by Table 8.15(b) during 1978.
B.
10 CFR 20.201(b). " Surveys," requires that "Such surveys be con-ducted as may be necessary to comply with the regulations contailed in each section of Part 20.
10 CFR 20.401(b), " Records of surveys, radiation monitoring, and disposal" states "Each Licensee shall maintain records in the same units used in this part showing the results of surveys required by 20.201(b)..."
Contrary to the above, the licensee made surveys for airborne radioactive material as required by a Special Work Permit (SWP) on May 10.1978 and records of the survey were not maintained by the licensee as required.