WISCONSIN INDUSTRI AL TESTING, INC.
~
5600 WEST HEMLOCK STREET f/- $MM.a MILWAUKEE. WISCONSIN 53223 (414) 353-0607 December 11, 1978 U. S. Nuclear Regatatorj Commission Washington, D. C.
20555 Gent.Lemen:
Enclosed.is a description of the Wisconsin Industrial Testing, Inc. qualibj assurance program for shipment of type B paciuges under NRC Materiais License 48-17480-01.
This description b being filed punsaant to 10 CFR 71.24, which is not listed in Part 170, therefore, it is assumed that submission of a License fee is not rzquired.
Sin a
d
/
Roe C. Combs,Jr.
President and Pndiation Safeb) Officer
&~g.
RC/pai..
%/
l s
n..
~
G..
~
li
-s a
\\
w ; --. -
11gy5 7901170118 C
Attachment L Description of Quality Assuunce Program for Type B QuantiLJ Shipments of Radioactive Material 1.
Organi:ation
- a. blisconsin Industrial Testing, Inc. putsuant to 10 CFR 71.12 and 10 CFR 71.51 (a) is responsible for a QA Program for Type B quantity shipments and transportation of radioactive material. FabrienPan and design of Type 8 packages are not included.
- b. The organisatinnat sttueture in Attachment H is applicable.
- 1) The Rndintinn Safe.ty Officer is responsible for administration of he program, btaining of peMonnel, procurement af manufactater*s certificat. ions, mintaining pnehnnLng and shipping documents, retention of records and program artditA.
2)
Radiographen are responsible for handling, storage, shipping and transporting radioactive packages in accordance salth the procedures in Attachment E: and key are responsible fo.t inspection, surveying and maintenance reports in accordance salth the procedures h Attachment E.
2.
QualLty Assurance Program
- a. Radiographers are trained in their raponsibiti. ties above according to Attachment F.
- b. The QA program sciLL be viable,.tequiring mnagement approval, and be program encompasses specific requirements s. tat.ed in the package approval for use, and general radiation safety and shipping requi.tements.
- c. Mannfacturer's certifications scill be requested and maintained on all NRC Type 8 packages manufactured and procured after January 1,1979.
3.
Document Control
- a. Packaging, shipping, inspection and handling insttuctions fram ue manufactureu scill be mintained for each model Type 8 package,
- b. The RSO shallinsure hat the shipment and L1ansportation of Type 8 packages is conducted in accordance teith the above documents.
4.
Handling, Shipping, Transporation and Storage
- a. Radiography peuonnel scill handle, ship, Ltansport, and st. ore radioactive packages in accordance saith the proceda,tes in Attachment E.
- b. Radiography personnel sciLL determine the completeness of package inspestions and presence of manufacturer's certificates beforeshipment.
Original L-1 Dec 11, 78 11t39
- 5. Inspections, Surveys and Maintenance Reports
- a. Inspections, surveys and cnin.tenance reponts on Type B packages witt be made in accordance with Attachment E procedures.
- b. Quarterly inspection and maintenance of Type B packages wilt. be perfarned by the RSO as ou.tLined in Attachment H.
- 6. Quality Assurance Records
- a. UtiUratinn togs, shipment records, packages surveys, and quarterly inspection records will be maintained as spt.ctfLed in Attachments E cud H.
- b. Training records are maintained in accordance with Attachment H.
- c. Equipment and package, procedures and inst. ructions are meintained by the Radiation Safe 2.y 0fficer.
- 7. Audits
- a. Quarterly audits of the entire edininn safety program of Wisconsin Industrial Testing, Inc. is performed in accordance with Attachment G.
- b. These quarterly audits include the necessary checks on the QA program as outlined in Attachment H.
Original L-2 Dec 11, 78
~
WISCONSIN INDUSTRI AL TESTING, INC.
5600 WEST HEMLOCK STREET MILWAUKEE WISCONSIN 53223 (414) 353-0607 Suppt.emeJtt 2 PAGE reb (0VE INSERT L-1 ORIG.
- DEC. 11, 1978 L-2 ORIG.
- DEC. 11, 1978 11675
s.
EiEE m
i W Ex w ~e?.'
m.M
-g 2
- r.W M. CC.s,
-w t.
t h./g,,..<.. c l
w w
...-....,. ~ ir >..,. _
~=; r= ~ - - - - - - - ~. -
-~
- p. 7 a 9.' : 1%@; - '
g.
m,
- i
,,a. -..,. y.. :.. - m _-m
. >,v-f;g y;.
.g
~
y
~U gv
- g.
g&, _,
, (. -
,, +y e
- s. ~.
..., "_/.
jg79j.'*
~~'""5
,g g l
., m.
.., c.
,,m..
y,..,~E979 0,9, UN4.. g
_,, w n '\\ -~~~7 ;
~~~
jgy 5l
- ~~- -
t o
~ ~ ~ ' '
\\.
^ '
\\
l PM
.a..
- pyl 1
i
=
,;g
.y
'. ':... W.
,a
..t
-v..
.r
,. g. -
.:. ; c ;. -.
4..
1
- '.y y; :;L..,. ;.,
e.,
- p.
c:.
yy e
. +..
p.
WISCONSIN INDUSTRI AL TESTING, INC.
N'-';
. W j
'.kr MILWAUKEE WISCONSIN 53223 5600 W HEMLOCK STREET
- i HEIUHN REQUESTED J
1
i To TRANSPORTATION BRANcII b
DIVISION OF FUEL CYCLE AND 1%TERIAL SAFETY Q u;.
0FFICE OF NUCLEAR MATERIAL SAFETV AND fr,'..ta
'~
IV '
SDFCGUARDS U.S. NUCLEAR REGULATORY COMMISSION WASIllNGTON, DC 20555 t
YOUR ORDI R NO OUR ORDF R NO _._
e